Display of the functional statuses
Status
Device status
Condition
Auxiliary
condition
Subsequent
status device
LED status
green
LED status
red
LED alarm
red
A0
Device
on
Idle process
Ready for operation
A0
10ms
every 2s
1
Off
Off
A1
System error
A1
Off
10ms
every
2s
1
Off
A2
Critical battery status
A2
Off
10ms
every
2s
1
Off
A3
Exceeding an alarm
threshold
A3
Off
Off
10ms
every
2s
1
B1
Device
on
Pressing Control
button
t < 3 s
Measurement active
A0 or A3
1 s
Off
-
B2
Measurement inactive
A0 or A3
100ms
every
200ms
Off
-
B3
Alarm event present
A3
-
-
1 s
B4
System error
A1
Off
1 s
-
Critical battery status
A2
Off
1 s
-
B5
Pressing Control
button
3 s ≤ t < 5 s
Without active
switch-off protection by
password
Ax or B6
Off
Off
100ms
every
200ms
B6
Pressing Control
button
t ≥ 5 s
C0
Off
1 s
Off
B7
Pressing Control
button
t ≥ 3 s
With active
switch-off protection by
password
Ax (switch-off
prevention
through a
password)
Off
Off
Off
C0
Device
off
C0
Off
Off
Off
C1
Pressing Control
button t < 3 s
C0
Off
Off
Off
C2
Pressing Control
button
t ≥ 3 s
Battery cell empty
C0
Off
Off
Off
C3
Without active
switch-on protection by
password
Ax
2 s
Off
Off
C4
With active
switch-on protection by
password
Ax after valid PW
entry via software
in 60s;
C0 without PW
entry after 60s
1 s every
2 s
Off
Off
C5
Clock not set after
changing the battery
A1
Off
2 s
-
C6
Battery cell low
C0
Off
7 x 1 s
flash
-
D0
Device
on
Measurement
data recording
Ax
On
Off
Off
1
The cyclic device flashing can be switched on/off via the MONILOG
®
Analyzer software (see section 4.3.8).