Instruction Manual

MicroShockDetector plus
- 7 -
2. T E C HN I C A L P A R A M E TE R S
Shock parameters
200 data records with the highest space vector amplitude, of which
the 10 highest values with a curve-plots over 4 s, resolution 2 ms
Acceleration sensor
3D-MEMS, measuring range ±14 g, 1mg resolution, accuracy:
±(2% measuring range and 5% measurement value) at 13Hz/20°C;
±(3% measuring range and 6% measurement value) at 13Hz/+60°C
Registration threshold from 0.25 g
Lower limit frequency 1 Hz
Upper filter cut-off frequency set up fixed at 25 Hz
Shock classification
Subdivision of shocks according to space vector amplitude into
classes, number of shocks not limited;
>0,25; >0,5g; >1g; >1,5g; >2g; >3g; >4g; >5g
Temperature
measurement
-40°C to +65°C ±1 K;100,000 measurement values
Relative humidity
0 %RH - 100 %RH ±3 %RH, 100,000 measurement values
Air pressure
260 1260 mbar ±2 mbar, 100,000 measurement values
Light
0 lx 65000 lx ±10 %, 100,000 measurement values
Indication
2 LED‘s, for status and alarm limit-value overshooting
Operating elements
1 button for status indicator, ON/OFF switching with password
protection
Connections:
Mini USB 2.0
Interfaces
NFC;
Status report can be read out via NFC with a smartphone and the
free “Monilog Connect” app;
Save and/or send the PDF report via email
Operation and
storage conditions:
-40°C to +65°C; max. 98% rel. air humidity
Power supply
1 exchangeable lithium battery cell, 3,6 V type LR06 (AA, Mignon),
lithium content ~0,7g
Duration of up to 3 years in the switch-on period (depending on the
device configuration)
Data storage
Receipt of measuring data independent of battery cell status for a
minimum of 10 years
Dimensions
106mm x 48mm x 33mm (LxWxH)
126mm x 48mm x 40mm (LxWxH with magnetic feet)
Housing
Plastic housing with stainless steel base
Weight
approx. 172 g, (258g total if mounted on magnetic feet)
Protection type
IP67
Calibration
Manufacturer’s calibration valid for 2 years, unless otherwise agreed.