Manual
Technical Data
6-3
Positioner SIPART PS2/SIPART PS2 PA
C79000-G7476-C150–01
Electrical data: basic instrument without PROFIBUS PA
6DR4000–1N/–2N and
6DR4001–1N
6DR4000–1E/–2E and
6DR4001–1E
Degree of protection acc. to
EN 50014 and EN 50020
– II2G EEx ib II C T4/T5/T6
Place of installation – zone 1 + 2
Ambient temperature – 30 to + 80 °C T4 – 30 to + 80 °C
T5 – 30 to + 65 °C
T6 – 30 to + 50 °C
2-wire circuit Fig. 3-8 Fig. 3-16
Nominal signal range 4 to 20 mA
Current for maintenance of
power supply
w 3.6 mA
Required load voltage U
B
w 10 V without HART module
U
B
w 11.5 V with HART module
Static destruction limit " 40 mA –
Internal capacitance C
i
– 19 nF
Internal inductance L
i
– 0.22 mH
For connection to intrinsically
safe current sources
with U
i
– v 30 V
J
i
– v 100 mA
P
i
– v 1 W
3/4-wire circuit Fig. 3-9
Power supply U
H
Range + 18 to 35 V + 18 to 30 V
Power consumption J
H
Static destruction limit " 35 V –
Internal capacitance C
i
– 19 nF
Internal inductance L
i
– 0.22 mH
For connection to intrinsically
safe current sources
with U
i
– v 30 V
J
i
– v 100 mA
P
i
– v 1 W
U
H
– 9.2 V
J
H
=
1.5 kΩ
[mA]