Specifications

Table Of Contents
RMX 1500/2000/4000 Release Notes for Maximum Security Environments - Version 7.5.0.J
256
355
Upgrade
Process
VNGR-
18242
When upgrading RMX4000
with 4 MPM+ cards from
Version 7.0.0.162 to
Version 7.0.2.61
Two of the MPM+ cards
remain in startup mode
and do not complete the
upgrade.
V7.0.2
356
Upgrade
Process
VNGR-
18272
When downgrading an
RMX 4000 with 4 MPMx
cards from version
7.0.2.64 to version
7.0.1.16, the IMPC is burnt
on only three out of four
cards and the fourth card
appears with voltage
problem.
V7.0.2
357
Upgrade
Process
VNGR-
18276
When upgrading an RMX
2000 with one MPM card
from version 7.0.1.16 to
version 7.0.2.64, the MPM
card appears to be in
normal state in the
Hardware Monitor but with
no available units. The
status LED on the card is
green as in normal status.
The upgrade procedure
takes longer to complete,
and until it does the audio
controller units cannot be
used.
V7.0.2
358
Upgrade
Process
VNGR-
18278
No access to RMX 2000
after software upgrade
from version 7.0.2.61 to
version 7.0.2.64.
V7.0.2
359
Upgrade
Process
VNGR-
9565
When downgrading from
version 4.0 to version 3.0,
the MPM card does revert
to normal.
V4.0.0
360
Upgrade
Process
VNGR-
9740
When upgrading from
version 2.0.2 to version
4.1, and then Restoring the
Factory Defaults, during
system restart sometimes
MPL failure is
encountered.
V4.0.0 Turn the MCU
off and then
turn it on
("hardware"
reset)."
Table 8 Version 7.0.2 System Limitations
# Category Key Description
Detected
in Version
Workaround