Specifications

ACCESSORIES
YOU MAY
NEED
Check
the
list below
and see
your
MPI
dealer
for
accessories
you may
need
or
want
for
installation
of
your
heating-
system.
/K
CAUTION:
Only
use the
flue
pipe
supplied
with
the
Monitor 2400,
or the
approved
accessory
kits
available
from
your
Monitor
or
dealer.
ACCESSORY
Medium Adjustable Flue Pipe
Kit
Long Adjustable Flue Pipe
Kit
Lifter Pump
Extra
Short, Short, Medium
or
P/N
8051
P/N
8052
P/N
1101
APPLICATION
For
use
where wall thickness
is up to 12
/4
inches
For
use
where wall thickness
is up to 20
inches
For
use
with large capacity
tank
where gravity feed
is not
practical
For
use
where "standard"
installation
is not
practical
Long Extension
Kit or
Elbow Adapter
Kit
(See
Flue Pipe Extensions, page
7)
Fitting
and
Tank
For
large
capacity
fueling:
To be
dealer
installed
EXTENSION
KIT
LENGTH
Extra
Short Extension
Kit
Short
Extension
Kit
Medium
Extension
Kit
Long
Extension
Kit
P/N
82
12
P/N
8004
P/N
8003
P/N
8002
7!/6
to
1
1
1/2
inches (18.2
to
29.2cm)
1 1
1/2 to
20'/4
inches (29.2
to
51
.4cm)
20!/4
to 38
inches
(51
.4
to
96.5cm)
38
to 73
inches (96.5
to
185.4cm)
FLUE
PIPE EXTENSIONS
Four
standard extension
kits
are
available
from your
Monitor dealer. Most
installations
can be
made with
one
of
these
kits.
In
special
cases, custom
installations
may
be
required. These
may be
made
with
components
purchased from your dealer.
In
any
installation
the
following limitations MUST
NOT
BE
EXCEEDED.
1.
The
total length
of the
intake
or
exhaust pipe should
not
exceed
10
feet (3m) with
3
elbows,
13
feet
(4m)
with
2
elbows,
or 16 1/2
feet
(5m) with
1
elbow.
2.
These elbows should include
the one
used
at the
heater
but not the one on the air
supply hose
nor the
integral bends
in the
flue pipe. (See Figure
2)
3. The
correct damper
as
shown
on
Page
13
must
be
used.