Specifications

MONITOR
HEATING SYSTEMS
Section
1:
Description
1-36
COMBUSTION
BLOWER
MOTOR
The
combustion blower
has a
four stage intake
fan
Burner
modes control
fan
speeds.
The
combustion
air
controls
are as
follows:
Table
1-2
COMBUSTION
AIR
CONTROL
Burn
Mode
Fan
Speed
(r.p.m.)
High 2,975
Medium-High
2,550
Medium-Low 2,025
Low
1,800
1-37
OVERHEAT
PROTECTOR
SWITCHES
Connected
in
series,
two (2)
normally-closed
Over-
heat
Protector Switches safeguard
the
heaters
against damage
due to
overheating.
The
switches
are
rated
110'C
(230T)
and
105'C
(221
'F).
Should
a
Monitor overheat
(internal
temper-
atures
rise
beyond 105'C
(221'F).
either
or
both
switches
will
open
to
shut down
the
heater.
After
ex-
tinguishing
the
flame,
the
code
[EOS]
is
indicated
in
the
digital
display.
The
Overheat Protector Switches
will
automatically reset after
cooling
down.
Once
the
heater
has
cooled
to
90'C
(194T),
the
system
can be
restarted.
To
restart
the
Monitor,
proceed
as
follows:
A.
Press ON/OFF Switch
to
OFF.
B.
Allow heater
to
cool.
C.
Troubleshoot
the
cause
of the
overheat.
D.
Press
ON/OFF
switch
to ON
E.
Proceed with normal
operation.
8