Specifications

MONITOR HEATING SYSTEMS
Section
2:
Installation
Applicable
Wall
Thickness
of
Flue Pipe.
The
flue
pipe
attached
to the
heater
can be
installed
in the
wall thickness from
0.6in.(1.5cm)up
to
8.5in.(22cm).
In
case
the
flue pipe will
be
installed
in the
wall thick-
ness
more
that
8.5in.,
the
optional part, Flue Pipe
Kit
should
be
used.
For
the
types
of
flue pipe kits
and
their applicable
wall
thickness, please
refer
to
Table 2-3.
Standard
Flue
Pipe
Thickness
of
walls
1.5cm
~
12.5cm
0.6in~5in
Thickness
of
walls
12.5cm~22.0cm
Sin
~8.5in
Flue
Pipe
A
,Sleeve
Nut
nrK
/Flue
Pipe
B
Since
the
installing
dimension
can not
be
decrease
to
less
than
Sin.
(12.5cm),
fix
the
flue
pipe
by
using
the
Sleeve
Nut
attached
to
the
heater.
s
Wall Thickness
1.5
cm -
12.5
cm
Flue Pipe
A
Flue Pipe
B
y/\<Z.
Wall Thickness
12.5
cm -
22.0
cm
Medium
Adjustable
Flue
Pipe
Kit
Thickness
of
walls
22.0cm~31.5cm
8.5in~12.5in
Flue
Pipe
A
A
Medium
Adjustable
Flue
Pipe
B
(P/N.8051)
s£r-
Wall Thickness 22.0
cm -
31.5cm
Long
Adjustable
Flue Pipe
Kit
Thickness
of
walls
31.5cm
~
50.5cm
12.5in~20in
Flue
Pipe
A
Relay
Pipe
(P/No.8052)
Flue Pipe
B
Wall Thickness
31.5cm~
50.5cm
Table.
2-3
A
CAUTION
Please
be
sure
to
observe
the
instruction
for the
types
of
Flue
Pipe
Kit and
their
installing
wall
thick-
ness.
Do
not
install
any
fuel pipe
kit
beyond
its
maximum
applicable wall thickness, since
the
connection
of
Flue
Pipe
A
with
Flue
Pipe
B, or
Flue
Pipe
A, B, and
Relay
Pipe
will
be
incomplete,
it
will
create
a
hazard
because
of
exhaust
gas
leakage.
16