Specifications

MONITOR
HEATING SYSTEMS
Section
2:
Installation
2-10 INSTALLING
AN
EXTENSION
KIT
Installing
an
Extension
Kit
requires
the
construction
of
an air
line
and the
exhaust
line.
The air
line
is
connected between
the Air
Supply Elbow
at the
rear
of
the
heater
and the air
inlet port
on the
Flue
Pipe.
Similarly,
the
exhaust
line
is
connected
between
the
joint pipe
at the
rear
of the
heater,
and the
exhaust
port
on the
Flue Pipe.
IMPORTANT:
The PVC air
line
is
longer
than
the
exhaust
line
and may
need
to be cut
to
size.
Be
sure,
however,
to
thor-
oughly
deburr
all
rough
edges.
10
Part
No.:
8002 Long Extension
Kit 38 to 73
inches
8003 Medium Extension
Kit
20
^A,
to 38
inches
8004 Short Extension
Kit
11
>£
to
20
>J
inches
8212
Extra Short Extension
Kit
7^
to
1l)i
inches
Figure
2-10 COMPONENTS
OF
EXTENSION
KIT
ITEM?
DESCRIPTION
1
PIPE,
Air
supply
2
JOINT,
Air
line
3
ELBOW
90
Air
line
4
LEG,
Wall-standoff
5
PIPE
CLAMP,
Top
ITEM;
6
7
8
9
10
DESCRIPTION
PIPE
CLAMP,
Bottom
SCREW.
Legs,
mounting
SCREW,
Pipe
Clamp
BOND. Adhesive
EXHAUST
INSULATING
SOCK
18