Specifications
MONITOR
HEATING
SYSTEMS
Section
1:
Description
1-1
SPECIFICATIONS
Model
Fuel Type
Heater
Efficiency
Heat
Rating
Heater
Output
Fuel Tank
Fuel
Consumption
Power
Source
Power
Consumption
Heated
Air
Delivery
Vent
Pipe Hole
Dimensions
Weight
* Net
Efficiency
is
88%, A.F.U.E.
is 84%
Monitor
2400
Crystal
Clear
Kerosene
93%*
High
:
43,000 BTU/hour
H.Medium
:
32,000
BTU/hour
L.Medium
:
24,600 BTU/hour
Low:
16,200
BTU/hour
High
:
37,200 BTU/hour
H.Medium:
26,900 BTU/hour
L.Medium:
20,700 BTU/hour
Low:
13,600
BTU/hour
Separate
(Not supplied with heater)
High
:
0.319
Gallon/hour
H.Medium:
0.24 Gallon/hour
L.Medium:
0.18
Gallon/hour
Low:
0.12 Gallon/hour
120
Volts
AC
;60Hz
Ignition
: 310
Watts
High combustion Operation
: 68
Watts(Average)
High
to Low 4
steps
combustion
:
56.5
Watts(Average)
Operations
High
: 388
Cubic feet/minute
H.Medium
: 388
Cubic feet/minute
L.Medium
: 330
Cubic feet/minute
Low
: 300
Cubic feet/minute
-inches Diameter
Height:
26.6 inches
Width:
28.7 inches
Depth
:
14.0
inches
82
Pounds, empty
1-2
SPECIAL FEATURES
AUTOMATIC
IGNITION
MEMORY
BACK
UP : Set
Memory
can be
kept
in
case
of
power
failure
for up to 30
minutes.
DUAL
BLOWERS
:
Separate fans
for
combustion
and
room
air
circulation.
THERMOSTATICALLY
CONTROLLED
:
Adjusts
to
the
desired room temperature.
BUILT-IN TIMER
:
Heater
will
automatically operate
as
programmed
by the
user.
AUTOMATIC
RESET AFTER POWER FAILURE
:
Heater
will
automatically resume operation after
power
is
restored.
INDICATOR
LIGHTS
:
Easy-to-see
signals show
when heater
is in
operation, when timer
is
activa-
ted,
and
when
the
burner
is
operating.
CHOICE
OF
FUEL SUPPLY
:
Connect
to
separate
tank.
MULTIPLE HEAT EXCHANGER
:
Extracts
88% of
heat
from burner.
CLEAN
OPERATION
:
Products
of
combustion
are
vented outside.
CONSUMES
NO
RpOM
AIR : Air for
combustion
is
drawn
from
outside.
EASY
INSTALLATION
:
Includes
all
parts required
for
standard
installation.
CHILD
LOCK
:
Prevents accidental operation
and
prevents
small
children
from
altering
the
controls.
1-3
SAFETY FEATURES
SAFE
RE-LIGHTING
:
Heater
will
not
restart
until
its
combustion chamber
has
cooled.
ELECTRICAL
PROTECTION
:
Heater automatically
shuts
off in the
unlikely
event
of a
malfunction
in
the
electrical
circuitry
or
disruption
of the
power
supply.
NO
EXHAUST
IN
ROOM
:
Products
of
combustion
are
discharged outdoors.
FLUE PIPE
:
Outside
air is
drawn through
a
pipe-
within-a-pipe
venting system. This process
pre-
heats
combustion
air
and
regains heat from
ex-
haust gases.
ZLCAUTIONiALTERNATE
POWER
SOURCES
The
Monitor 2400
may not
operate when pow-
ered
by
sources such
as an
auxiliary generator,
UPS
(Uninterrupted Power Source), inverters,
etc. Check with your dealer
for
guidance
on
spe-
cific
applications.