Specifications

MONITOR HEATING SYSTEMS
Section
5:
Servicing
NOTE:
Make
sure
the
position
of
flame
detector
rod is
centered
between
combustion
ring
and
burner
pot
before
reassembling.
(See
Figure
5-5)
Flame
Detector
Rod
Combustion
Ring Assy
a*
V'
Burner
Figure
5-5
NOTE:
If
flame
rod is
sooted
or has a
carbon coat-
ing it can be
cleaned with steel wool
or a
find sand paper.
For
minor adjustments
of
flame detector
rod
without
disassembling
any
components:
1.
Loosen
the two
retaining screws about half
to one
full
turn.
2.
Tightening
down
on the top
screw first
will
cock
the rod
outward
away
from
the
combustion
ring.
Tightening
the
bottom screw first
will
cock
the rod
inward towards
the
combustion
ring.
Combustion
Chamber
Gap
4mm(0.16")
or
more
5-5
CLEANING
THE
FUEL INLET
When
cleaning
the
combustion chamber
and the
burner
pot,
the
fuel
inlet
nozzle
should
also
be
cleaned. This
can be
done
as
follows:
1.
Disconnect copper
fuel
line
at bum
chamber.
2.
Push
a
piece
of
wire (about
the
same size
as the
I.D.
of
fuel
inlet
pipe)
into
the
fuel inlet nozzle.
3.
If
obstruction
is
felt twist wire back
and
forth
(to
brake
up
soot
and
carbon)
so
that wire
ultimately
penetrates igniter
shield.
45