SPECIFICATIONS
Model
Monitor
2200
Fuel Type
Red
dyed
or
Clear Kerosene
or Low
Sulphur
*1 Oil
Heater
Efficiency
93%*
Heat
Rating
High
:
22,000
BTU/hour
H.Medium
:
17,400
BTU/hour
L.Medium
:
12,400 BTU/hour
Low:
9,600 BTU/hour
Heater
Output
High:
18,260 BTU/hour
H.Medium
:
14,440 BTU/hour
L.Medium
:
10,290 BTU/hour
Low:
7,970 BTU/hour
Fuel
Tank
Separate
(Capsule
tank optional)
Fuel Consumption
High:
0.164
Gallon/hour
H.Medium
:
0.13 Gallon/hour
L.Medium
:
0.19
Gallon/hour
Low:
0.07
Gallon/hour
Power
Source
120
Volts
AC ;
60Hz
Power
Consumption
Ignition
: 250
Watts
Operations
: 41
Watts (Average)
Heated
Air
Delivery
High
:
176
Cubic feet/minute
H.Medium
:
176
Cubic feet/minute
L.Medium
: 126
Cubic feet/minute
Low
:
113
Cubic feet/minute
Vent
Pipe Hole
inches
Diameter
Dimensions
Height:
26.0 inches
Width
:
20.9 inches
Depth
:
13.0
inches
Weight
55
Pounds, empty
*
When
considering heat
of
condensation
is
lost, then
the net
efficiency
is
88%, A.F.U.E.
is 84%
1-5
SPECIAL FEATURES
AUTOMATIC
IGNITION
MEMORY
BACK
UP : Set
Memory
can be
kept
in
case
of
power failure
for up to 30
minutes.
DUAL
BLOWERS
:
Separate fans
for
combustion
and
room
air
circulation.
THERMOSTATICALLY
CONTROLLED
:
Adjusts
to
the
desired room temperature.
BUILT-IN TIMER
:
Heater
will
automatically operate
as
programmed
by the
user.
AUTOMATIC
RESET AFTER
POWER
FAILURE
:
Heater
will
automatically resume operation after
power
is
restored.
INDICATOR
LIGHTS
:
Easy-to-see
signals
show
when
heater
is in
operation, when timer
is
activa-
ted,
and
when
the
burner
is
operating.
CHOICE
OF
FUEL SUPPLY
:
Connect
to
separate
tank
or
capsule tank
optional.
MULTIPLE HEAT EXCHANGER
:
Extracts
88% of
heat from
burner.
CLEAN
OPERATION
:
Products
of
combustion
are
vented
outside.
CONSUMES
NO
RpOM
AIR : Air for
combustion
is
drawn
from outside.
EASY
INSTALLATION
:
Includes
all
parts required
for
standard
installation.
CHILD LOCK
:
Prevents accidental operation
and
prevents
small children from
altering
the
controls.
1-6
SAFETY FEATURES
SAFE
RE-LIGHTING
:
Heater
will
not
restart
until
its
combustion chamber
has
cooled.
ELECTRICAL
PROTECTION
:
Heater automatically
shuts
off in the
unlikely event
of a
malfunction
in
the
electrical circuitry
or
disruption
of the
power
supply.
NO
EXHAUST
IN
ROOM
:
Products
of
combustion
are
discharged
outdoors.
FLUE
PIPE
:
Outside
air is
drawn through
a
pipe-
within-a-pipe
venting system. This process
pre-
heats
combustion
air and
regains heat from
ex-
haust gases.
&CAUTION:ALTERNATE
POWER
SOURCES
The
Monitor 2200
may not
operate when pow-
ered
by
sources such
as an
auxiliary generator,
UPS
(Uninterrupted
Power
Source),
inverters,
etc. Check with your dealer
for
guidance
on
spe-
cific applications.