Specifications
MONITOR
HEATING SYSTEMS
Section
6:
Troubleshooting
|
M-2400
Resistance
values
COMPONENT
APPROX. OHMS
Igniter (connector
B/
B)
12.7
Power
Transformer—Primary
(AC
120V)
"Blue"
&
"Blue" Connector
H 141
Power
Transformer—Secondary
(AC
12V)
"Yellow"
&
"Yellow"
Connector
R
1.9
Power
Transformer—Secondary
(AC
120V)
"White"
&
"White" Connector
R 590
Circulation
Fan
(LEAD WIRE "WHITE
"&"
BLACK")
124
Circulation
Fan
(LEAD WIRE "BLACK
"&"
BLUE")
270
Combustion Blower (LEAD WIRE "WHITE
"&"
GRAY")
41
Combustion Blower (LEAD WIRE "GRAY
"&"
ORANGE")
78
Thermistor
(connector
Q/Q,
at
77'
F)
10,000
Fuse
2A
(read with fuse
out)
0.1
Fuse
10A
(read with fuse
out) 0.01
Solenoid Pump (Bypass resistor
at
pump
and
read
accross
coil)
565
WARNING:
DISCONNECT HEATER FROM POWER SOURCE
BEFORE
MAKING
ANY
RESISTANCE TESTS.
49