Specifications

MONITOR
HEATING
SYSTEMS
Section
6:
Troubleshooting
|
M-2200
Resistance values
COMPONENT
APPROX.
OHMS
Igniter
(connector
B/B) 16.8
Power
Transformer-Primary
(AC
120V)
"Blue"
&
"Blue"
Connector
H 141
Power
Transformer-Secondary
(AC
12V)
"Yellow"
&
"Yellow"
Connector
R
^.9
Power
Transformer—Secondary
(AC
120V) "White"
&
"White" Connector
R 590
Circulation
Fan
(LEAD
WIRE "RED
" & "
BLACK")
430
Circulation
Fan
(LEAD
WIRE
"BLACK
" & "
YELLOW")
420
Combustion Blower
(LEAD
WIRE
"BLACK"
& "
BLACK")
112.
Thermistor (connector
Q/Q,
at
77'F)
10,000
Fuse
2A
(read with fuse out)
0.1
Fuse
10A
(read with fuse out) 0.01
Solenoid Pump (Bypass resistor
at
pump
and
read
accross
coil)
990
WARNING:
DISCONNECT
HEATER
FROM POWER SOURCE
BEFORE
MAKING
ANY
RESISTANCE TESTS.
Component
Voltage Readings
COMPONENT
Thermistor
Thermistor
Air
Pressure
Switch/
Overheat
Protector Closed
Air
Pressure
Switch/
Overheat
Protector Open
Solenoid
Pump
Circulation
Fan
High Speed
Circulation
Fan Low
Speed
Igniter
Power
Transformer
(primary
side)
Power
Transformer
(secondary side)
Combustion
Blower
High Speed
Combustion Blower
Low
Speed
*
Pulse
can
only
be
measured
READING TAKEN
AT
Q
on PCB
Sensor disconnected
Q on PCB
Sensor connected
Connector
J
Connector
J
K
on PCB
RD
to BK
RD
to BK
Bon PCB
AC
120V
AC
120V
AC
12V
F on PCB
F on PCB
with
a
high
impedance
digital
volt meter.
AC
110
0
110
90
110
110
120
12
80
62
DC
5
1.5-3.2
pulse*
51