Specifications
MONITOR
HEATING
SYSTEMS
Section
6:
Troubleshooting
TEST
POINT
VOLTAGE
\Operation
\Mode
Test
Point
N,
TP2
TP3
TP4
TP5
TP6
TP7
Preparation
5V±10%
12V±30%
1.5-3.2V
pulse
OV
pulse
at
plugin
Pre-purge
Pre-heat
5V±10%
12V±30%
1.5-3.2V
pulse
OV
5V
Igniting
low
med
2
min.
5V±10%
12V±30%
1.5-3.2V
pulse
infinitly
variable
- 5V
Pre-burning
1
(C.F.M:Off)
5V±10%
12V±30%
1.5-3.2V
pulse
1.2V
min.
5V
Pre-burning
2
(C.F.M:Low)
5V±10%
12V±30%
1.5-3.2V
pulse
1.2V
min.
5V
\0peration
\Mode
Test
Point\
TP2
TP3
TP4
TP5
TP6
TP7
High
5V±10%
12V±30%
1.5-3.2V
pulse
1.2V
min.
5V
Medium-High
5V±10%
12V±30%
1.5-3.2V
pulse
1.2V
min.
5V
Medium-Low
5V±10%
12V±30%
1.5
—3.2V
pulse
1
.2V
min.
5V
Low
5V+10%
12V±30%
1.5
—3.2V
pulse
1.2V
min.
5V
OFF
5V±10%
12V±30%
1.5-3.2V
pulse
OV
5V
Post-purge
5V±10%
12V±30%
1.5—3.2V
pulse
infinitly
variable
5V
Waiting
until
Programmed
time
comes
on
5V±10%
12V±30%
1.5~3.2V
pulse
OV
5V
52