Specifications
MONITOR
HEATING
SYSTEMS
Section
6:
Troubleshooting
INDICATION
OF
FAILURE
MODE
Digital Display
EDI
cnc
L
U
J
cnc
/_/_//_/
EDB
C
O
L
U
E
H
C
1C
L
IJ
C
1C
/_
IU
The
Reason
of
Indication
At
pre-purge,
Flame
rod is
sensing flame
when
there should
be
none.
After
power
is
turned
on,
power supply
to
the
microprocessor
timing
circuit
is
incorrect.
At
starting
of
operation,
the
circuit
to
drive
photo
triac
of
Solenoid Pump
is
malfunctioning.
Revolutions
per
minute
of
Combustion
blower
is
malfunctioning.
No
ignition.
Rame
failure.
Power
supply voltage
too
low.
Load
failure
of
Combustion blower motor.
Trouble
Point
Flame sensing circuit, grounded flame
rod or
pinched wire.
Timer clock circuit
bad or
power cycles
(hertz)
to
unit above
or
below acceptable
levels.
Solenoid Pump control circuit
has a
malfunction.
Combustion blower
or
Combustion blower
control circuit
has a
malfunction.
Failure
of
Igniter, Solenoid Pump
or
circuit Board.
Incorrect wiring
or
flame
rod
touches
to
burner parts.
Air
pressure switch
or
overheat open.
There
are
obstacles
at
circulation
air
inlet
or
outlet.
Fan
cage
is
clogged with dust.
Inadequate fuel supply.
Voltage
too low or
Power
detector circuit
has
a
malfunction.
Flue Pipe
is
restricting
airflow.
62