Installation Guide
4 49-80512 Rev. 4
Installation Preparation
ADVANCE PLANNING
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH)RU
VDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRWH[FHHG
IWHTXLYDOHQWOHQJWKIRUDQ\GXFWFRQILJXUDWLRQV
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWRQSDJHWRFRPSXWH
WKHPD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH
outdoors.
Ŷ:KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQW
air system in accordance with local building code
requirements.
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
WARNING
725('8&(7+(5,6.2)),5(
86(21/<0(7$/'8&7:25.
Ŷ,QVWDOODZDOOFDSZLWKGDPSHURUURRIFDSDWWKH
H[WHULRURSHQLQJ2UGHUWKHZDOORUURRIFDSDQGDQ\
transition needed in advance.
Wall Framing for Adequate Support
Ŷ7KLVYHQWKRRGLVKHDY\$GHTXDWHVWUXFWXUDOVXSSRUW
must be provided in all types of installations. The hood
PXVWEHVHFXUHGWRYHUWLFDOVWXGVLQWKHZDOORUWRD
horizontal support.
Ŷ7KHYHQWKRRGVKRXOGEHRQVLWHEHIRUHILQDOIUDPLQJ
and wall finishing. This will help to accurately locate
the duct work and electrical service.
Ŷ,QVWDOODWLRQZLOOEHHDVLHULIWKHYHQWKRRGLVLQVWDOOHG
before the cooktop and countertop are installed.
ACCESSORY DUCT COVER
This hood is shipped with a decorative duct cover for
FHLOLQJKHLJKWVRIWR7KH=;GXFWFRYHU
accessory is available to reach ceiling heights between
DQG7KHDFFHVVRU\VKRXOGEHRUGHUHGZLWK
the hood and be on site before installation begins.
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING
)253(5621$/6$)(7<7+,6
$33/,$1&(0867%(3523(5/<*5281'('
Remove house fuse or open circuit breaker before
beginning installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWKWKLV
DSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRUSUHYDLOLQJ
local codes and ordinances.
Electrical supply
7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+]
DQGFRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHG
EUDQFKFLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW
breaker or time delay fuse.
Ŷ:LULQJPXVWEHZLUHZLWKJURXQG
Ŷ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH
proceeding.
Ŷ5RXWHKRXVHZLULQJDVFORVHWRWKHLQVWDOODWLRQORFDWLRQ
DVSRVVLEOHLQWKHFHLOLQJRUEDFNZDOO5HIHUWR:LULQJ
/RFDWLRQVRQSDJH
Ŷ&RQQHFWWKHKRRGZLULQJWRWKHKRXVHZLULQJLQ
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a
JURXQGHGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
CAUTION
$XWRPDWLFDOO\2SHUDWHG'HYLFH±7R
reduce the risk of injury disconnect from power supply
before servicing. This unit is equipped with an integral
disconnecting switch located inside the blower housing.