Specifications

– 28 –
(Continued next page)
Note: The sump clamping nut turns
counterclockwise and may be dif cult to remove. It
may be necessary to insert a screwdriver or other
tool between the clamping nut tabs to enable you to
apply suf cient torque to break the factory seal.
10. Remove the clamping nut.
11. Remove the sump gasket (not shown) and sump.
Clamp
Nut
Tabs
Tub Thermistor
The tub thermistor is located under the tub and is
attached to the left side of the sump with 2 lock
tabs. A thermal mastic is applied to the at side
of the thermistor where it makes contact with the
underside of the tub.
During the hot wash cycle, the thermistor senses the
water temperature and turns the heating element
off when the water reaches 128°F.
Note: If the thermistor is not operating, the hot
wash cycle will default to a set time for the heating
element to cycle.
The thermistor has a negative coef cient. As
the temperature at the contact point on the tub
increases, the thermistor's resistance decreases. The
thermistor has an approximate resistance value of
56.5K Ω at 72°F.
To remove the thermistor:
Note: Wear latex gloves to perform this repair.
Disconnect power.1.
Open the dishwasher door and remove the 2.
bottom rack.
Remove the dishwasher from its installation.3.
Lay the dishwasher on its back.4.
Disconnect the thermistor wire harness.5.
Wire Harness