Product specifications
48
Advance Planning for Warming Drawers
Installation Below a Single or Double Oven
The warming drawer may be installed below a single or
double oven. Observe the 1" minimum clearance above
the toekick, or 5" above the floor.
Side-by-Side Installation
Install two warming drawers in separate cutouts. Allow
2" minimum between cutouts.
Installation Below a Countertop
The warming drawer may be installed beneath a
countertop. Install the drawer 5" minimum above the
floor or 1" above the toekick. The recommended distance
from the floor to the bottom of the cutout is 23-1/4" for
undercounter installation.
Installation Below a Cooktop
The warming drawer is approved for installation below
specified cooktop models. A solid barrier and an air gap
between the cooktop and the warming drawer are
required. See note below.
Installation Below A Cabinet Drawer
The warming drawer may be installed beneath a cabinet
drawer. In this installation, a solid barrier should be
installed above the warming drawer to block access. Use
any solid material such as 1/4"-thick plywood. Allow at
least 1/4" air gap between the barrier and the top of the
warming drawer.
Note: Additional clearance between cutouts may be required. Check to
be sure that oven supports, above the Warming Drawer location, do not
obstruct the required interior 23-1/2" depth and 9-1/4" height.
*Note: When installing the warming drawer below a cooktop, a solid
barrier must be installed at least 1" from the lowest point of the bottom
of the cooktop burner box to the top of the cutout. Use any solid material
such as 1/4"-thick plywood. Allow at least 1/4" air gap between the
barrier and the top of the warming drawer.
Dim. A Dim. B
ZTD910 28-1/2" 30"
ZKD910 25-1/2" 26-3/4"
30" Warming Drawers
ZTD910SFSS
Stainless Steel
ZTD910BFBB Black
ZTD910WFWW White
27" Warming Drawers
ZKD910SFSS
Stainless Steel
ZKD910BFBB Black
ZKD910WFWW White
1" Min. Above Toekick or Adjust
to Oven Installation Height
A
2" Min.
Allow 5/8"
Overlap on
All Sides
B
10-1/2"
23-1/4"
23-1/2" Min.
Inside
Oven
Cutout
9-1/4"
2x2 or 2x4
Anti-Tip Block
Against Rear
Wall, 9" From
Floor to
Bottom of
Block
9"
Dim. A Dim. B
ZTD910 28-1/2" 30"
ZKD910 25-1/2" 26-3/4"
A
2" Min.
Allow 5/8"
Overlap on
All Sides
B
10-1/2"
23-1/4"
23-1/2" Min.
Inside
1" Min. Above Toekick
Oven
Cutout
2x2 or 2x4
Anti-Tip Block
Against Rear
Wall, 9" From
Floor to
Bottom of
Block
9"
9-1/4"
Electrical
Outlet 16" Max.
From Left Side.
Installation Below
a Drawer
23-1/2" Min.
Solid Barrier
1/4"
Air Gap
25"
1-1/2"
Cabinet
Top
36"
Countertop
Height
1" Min.*
A
9-1/4"
Electrical Outlet
42" Max. From
Right Side.
Solid Barrier
See Note
Electrical Outlet
Flush With
Side of Cabinet
7" Max.
9"
Install
2x4 or 2x2
Anti-Tip Block
Against Rear
Cabinet Wall
9" From Floor
to Bottom
of Block
7"
Install a Solid Barrier
and a 1/4" Air Gap
Above Warming Drawer
2"
Min.
Side-by-Side Installation
Dim. A Dim. B
ZTD910 28-1/2" 30"
ZKD910 25-1/2" 26-3/4"
Single
Oven
Double
Oven