General Cooktop Features
Gas burners. Dual-ring burners ensure even heat delivery,
and infinite controls maintain precise temperature settings
between 500 and 15,000 BTUs.
General Oven Features
30" main oven (4.0 cu. ft., 24" wide). Offers an 8-pass,
4000-watt broil element and a 6-pass, 3700-watt
bake element.
Self-cleaning. Press a button and turn the dial to set the
self-clean cycle. The door locks automatically and remains
locked throughout the five-hour cleaning process.
For additional details on product installation, warranty
coverage, care and maintenance, visit
Monogram.com.
30" Dual-Fuel Professional Ranges
ZDP30N4DSS (natural gas)
ZDP30L4DSS (liquid propane)
Overall Dimensions
(WxHxD in inches):
29-7/8 x 35-1/4 36 -3/4 x 26-3/4
Amps @ 240VAC 19.9
Approx. Shipping Wt. (lbs.) 396
Dual-Fuel Range Offers a
Gas Cooktop and an
Electric Oven
Natural or LP Gas Must Be
Specified by Model Number
A 1-1/2", 9" or 22" Backguard
Must Be Ordered with Range
Optional Wok Accessory
Advance Planning for 30" Professional Ranges
All Professional ranges are factory set for natural or
liquid propane gas. The correct model should be ordered
for the installation situation.
Note: Conversion kits (WB49X10082, Natural to LP and
WB49X10081, LP to Natural) are available if the wrong gas
type was ordered. The kits must be installed by a qualified
service technician at additional cost.
Accessory ZXWK22Y, 22" wok with lid and ring fits all
Professional ranges and cooktops.
Electrical Requirements
Ranges must be supplied with 208/240V, 60Hz, and connected
to an individual, properly grounded branch circuit protected
by a circuit breaker or time-delay fuse. Install a 25-amp circuit
for 30" ranges. The receptacle must be a NEMA 14-50R
device to accept the four-prong plug on the range.
12"
12"
Gas
Supply
30"
3-1/2"
3-1/4"
Electric
Supply
Locate gas and
electrical as shown.
Gas Supply
Natural gas models are designed to operate at 5" water
column pressure. A regulator is required at the natural
gas source to provide maximum of 7" water pressure to
the range regulator.
The liquid propane models are designed to operate at 10"
water column pressure. A regulator is required at the LP
source to provide maximum of 14" water pressure to the
range regulator.