Quick Specs

Product Specication Revised 10/19PAGE 3 OF 3
For questions about your
appliance, please call 1-800-626-2000.
34 1/2"
(87.6)
Min
underside of
counter to floor
35" (88.9) Max
24"
(61.0)
min cutout depth
CUTOUT INSTALLATION
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW
10 1/2" (26.7)
1 1/2" (3.8)
24 1/4" (61.6) Min
Flush Inset
9" (22.9)
Max
ELECTRIC
23 3/4" (60.3) Min
cutout width
ZDBC240NBS
34 1/2"
(87.6)
Min
underside of
counter to floor
35" (88.9) Max
24"
(61.0)
min cutout depth
CUTOUT INSTALLATION
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW
10 1/2" (26.7)
1 1/2" (3.8)
24 1/4" (61.6) Min
Flush Inset
9" (22.9)
Max
ELECTRIC
23 3/4" (60.3) Min
cutout width
ZDBC240NBS
CABINET CABINET
Dim. A
Front Edge of
Product Case
Front Face
Standard
Installation
110º
120º
In a standard installation, the
product will project forward of
adjacent cabinets. See Dim. A.
23 3/4" min.
CABINET CABINET
These products will fit flush to adjacent
cabinets when installed with a Dim. A - width
filler panel or cleat. The filler panel should be
recessed or set back behind the door and
even with the front edge of the product case.
110º
120º
Flush
Installation
Filler panel or cleat to be set
back even with front of case.
Front Edge of
Product Case
Dim. A
Front Face
24 1/4" min. width
stainless steel models
PRODUCT DIM. A
ZDWI240, ZDB1240 1"
ZDWR240, ZDBR240 1"
ZIB1240, ZIF1240 1"
ZIFS240, ZIBS240 1/4"
ZDOD240 1-1/4"
PRODUCT DIM. A
ZDWI240, ZDB1240 2"
ZDWR240, ZDBR240 1-3/4"
ZIFS240, ZIF1240 1-5/8"
ZDOD240 1-7/8"
ZIB1240, ZIBS240 2-5/8"
REFRIGERATION MODULES, TOP VIEW
INSTALLATION NOTES
INSTALLATION CUTOUT
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW
Installation Space
is module can be installed
beneath a countertop or can be
used free-standing.
For a standard installation of
Stainless Steel unit: e product
must be installed so that the front
face will project 1-3/4" forward of
adjacent cabinets.
For a flush installation of Stainless
Steel unit: Install a 1/2" wide filler
strip on the hinge side. e width of
the opening must be 24-1/4" wide.
Location Requirements
All Monogram Refrigeration
Modules may be closed in on the
top and sides as long as the front
is unobstructed for air circulation
and door swing.
Do not install these products where
the temperatures will go below 55°F
(13°C) or above 90°F (32°C).
Do not install where they will be
subject to direct sunlight, heat
or moisture.
ese products are not designed to
be stacked one over the other.
Side-by-Side Installation
For a complete refreshment center,
install a Monogram Wine Reserve
and Beverage Center together.
Products must operate from
separate properly grounded
receptacles.
See Installation Instructions for
side-by-side information.