Quick Specification

PAGE 3 OF 4
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Revised 3/21
All Dual-Fuel Professional Ranges are factory set for
natural gas.
NOTE
A propane conversion kit is included with the range.
High Altitude kit for operation above 6,000 feet (for
Natural and LP gas models), is available at an additional
cost. The conversion must be performed by a qualied
gas installer at additional cost.
HA NG Service Kit: WB28X39726
HA LP Service Kit: WB28X39727
INSTALLATION INFORMATION
Before installing, consult installation instructions
packed with product or online at Monogram.com
for current dimensional data. A 30" or 36" wide
professional vent
hood is recommended for installation over this range.
Install the hood 30" to 36" above the cooking surface.
ADVANCE PLANNING
Refer to dimensional drawings for appropriate
placement and necessary clearances when planning
the installation.
Working areas adjacent to the range should have
18" minimum clearance between countertop and
cabinet bottom.
Clearance between range and side wall or combustible
material must be at least 12" on each side.
Installation must conform with local codes. In the
absence of local codes, the range must comply
with the National Fuel Gas Code, ANSI Z223.1-990.
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall
on each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and
the bottom of the wall cabinet.
Non-Combustible
Material**
16"
Max.
18"
Min.
30" Min.
48" Minimum
to Combustibles
12" Minimum
Each Side
12" Minimum
to Adjacent Wall
HELPFUL TIPS
WARNING
Installations without a hood require 48" minimum to
combustibles. A custom hood installation with exposed
horizontal combustible surfaces must have an Auto-On
feature. Refer to hood installation instructions for specic
hood clearances.
The surface of the entire back wall above the range and below
the hood must be covered with a non-combustible material
such as metal, ceramic tile, brick, marble or other stone.
DIMENSIONS AND INSTALLATION
INFORMATION (IN INCHES)
** As dened in the National Fuel Gas Code (ANSI Z223.1/CSA B149.1,
Current Edition). Clearances from non-combustible materials are not part
of the ANSI Z21.1/CSA 1.1 scope and are not certied by CSA. Clearances
less than 12” must be approved by local codes and/or the authority having
jurisdiction.