Quick Specification

PAGE 4 OF 4
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Revised 3/21
BACKSPLASH
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. A custom,
non-combustible backsplash can be used.
OPTIONAL STAINLESS STEEL KNOB KITS
AVAILABLE
ZXPR36KKTSS - 30" and 36" Range
ZXPR48KKTSS - 48" Range
GAS PRESSURE REGULATOR
You must use the gas pressure regulator supplied with this
rangetop. For proper operations the inlet pressure to the
regulator should be as follows:
Natural Gas:
Minimum pressure: 6" of Water Column
Maximum pressure: 13" of Water Column
Propane (LP) Gas:
Minimum pressure: 11" of Water Column
Maximum pressure: 13" of Water Column
See installation instructions for more details
UTILITY LOCATIONS
12" min. to combustibles or 0" to
a non-combustible material above
the cooking surface
0" clearance
to a back or
side wall below
the cooking
surface
4-5/8"
7-3/8"11-3/8"
2"
2"
30"
6-1/2"
Universal Utility Locations
HELPFUL TIPSDIMENSIONS AND INSTALLATION
INFORMATION (IN INCHES)
Locate gas and electric as shown