Specification Sheet

PAGE 3 OF 4
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Revised 12/20
All Dual-Fuel Professional Ranges are factory set for natural gas.
NOTE
A propane conversion kit is included with the range. High
Altitude kit for operation above 6,000 feet (for Natural and LP
gas models), is available at an additional cost. e conversion
must be performed by a qualified gas installer at additional cost.
HA NG Service Kit: WB28X39726
HA LP Service Kit: WB28X39727
INSTALLATION INFORMATION
Before installing, consult installation instructions packed with
product or online at Monogram.com for current dimensional
data. A suitable overhead vent hood is required for models with
a grill and is recommended for all other models.
ADVANCE PLANNING
Refer to dimensional drawings for appropriate placement and
necessary clearances when planning the installation.
Working areas adjacent to the range should have
18" minimum clearance between countertop and
cabinet bottom.
Clearance between range and side wall or combustible
material must be at least 12" on each side.
Installation must conform with local codes. In the absence of
local codes, the range must comply with the National Fuel Gas
Code, ANSI Z223.1-1990.
HELPFUL TIPS
WARNING
Installations without a hood require 60" minimum to
combustibles. A custom hood installation with exposed
horizontal combustible surfaces must have an Auto-On
feature. Refer to hood installation instructions for specific
hood clearances.
e surface of the entire back wall above the range and below
the hood must be covered with a non-combustible material
such as metal, ceramic tile, brick, marble or other stone.
DIMENSIONS AND INSTALLATION
INFORMATION (IN INCHES)
60" Minimum
to Combustibles
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall
on each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and
the bottom of the wall cabinet.
Non-Combustible
Material**
16"
Max.
18"
Min.
48" Min.
12" Minimum
Each Side
12" Minimum
to Adjacent Wall
**As defined in the National Fuel Gas Code
(ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials
are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less
than 12” must be approved by local codes
and/or the authority having jurisdiction.
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA
B149.1, Current Edition). Clearances from non-combustible
materials are not part of the ANSI Z21.1/CSA 1.1 scope and are
not certified by CSA. Clearances less than 12” must be approved
by local codes and/or the authority having jurisdiction.