Quick Spec

ZEU30RSJSSMONOGRAM 30" TOUCH CONTROL ELECTRIC COOKTOP
Product Specification Revised 1/18
NOTES
STANDARD INSTALLATION
19 5/8" (49.9) min
19 3/4" (50.2) max
Cutout depth
8 1/4"
(21.0) min
6 1/2"
(16.5) min
5"
(12.7) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
13"
(33.0) max
28 1/2" (72.4) min
28 5/8" (72.7) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
30 " (76.2)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZEU30RSJSS
19 5/8" (49.9) min
19 3/4" (50.2) max
Cutout depth
8 1/4"
(21.0) min
6 1/2"
(16.5) min
5"
(12.7) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
13"
(33.0) max
28 1/2" (72.4) min
28 5/8" (72.7) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
30 " (76.2)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZEU30RSJSS
NOTES
A
Wall coverings, countertop
and cabinets surrounding
cooktop must be able to
withstand temperatures of
up to 200°F.
B
Minimum 30" clearance
from countertop to
unprotected overhead
surfaces, when no
ventilation hood is
installed.
C
When using a ventilation
hood above the cooktop,
see hood installation
instructions for minimum
overhead clearance
dimensions.
D
Minimum 15" of clearance
from countertop to
nearest overhead surface
on either side of cooktop.
Make sure to include any
lighting rail covers in
calculation.
E
Minimum 2" distance from
edge of cutout to nearest
adjacent side wall below
upper cabinets.
F
Install an approved
junction box where it can
be easily reached through
the front of the cabinet
where the cooktop is
located. IMPORTANT:
For serviceability, the
junction box must be
located where it will allow
considerable slack in the
48” long conduit.
G
Maximum 13" depth of
unprotected overhead
surfaces, when no
ventilation hood is
installed.
H
For Americans with
Disabilities Act (ADA)
forward approach
installation: Minimum 6
1/2" clearance between
the top of the countertop
and the enclosure. The
enclosure must be made
of at least 1/4" thick wood
material, and must have an
access panel installed in
order to provide access to
the junction box and
hold-down brackets, and
to allow for service of the
cooktop.
COUNTERTOP CUT-OUT DIMENSIONS ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
A
B
C
G
For more details refer to
the installation instructions
for this product.
E
D
F
H