Specifications

Listed by
Underwriters
Laboratories
ZGP304NRSS (NATURAL GAS)
ZGP304LRSS (LIQUID PROPANE)
MONOGRAM 30" ALL-GAS PROFESSIONAL
RANGE WITH 4 BURNERS
DIMENSIONS AND INSTALLATION INFORMATION
(IN INCHES)
Product Specification Revised 10/18
Universal Utility Locations
4-5/8"
11-3/8"
30"
7-3/8"
2"
2"
6-1/2"
Gas/
Electric
Gas/
Electric
10-1/2"
1-1/2"
12"
28-1/4" to
Beveled
Edge of Control
Panel Bullnose
27-1/2" to
Beveled Edge
- Maximum
Adjacent
Cabinet Depth
for
Flush
Installation
13/16"
30-36"
3-3/16"
Control Panel
Depth
28-1/4"
to Front of
Door
48-1/4"
with Oven Door
Open
31-1/16"
to Front of
Handle
35-1/4"
to
36-3/4"
7" Control
Panel Height
28-7/8"
to Front
Edge
Optional
Backsplash
Accessories
ELECTRICAL REQUIREMENTS
Ranges must be hooked up to a 120V, 60Hz properly
grounded dedicated circuit protected by a 15-amp circuit
breaker or time-delay fuse.
OPTIONAL BACKSPLASH ACCESSORIES
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. A custom,
non-combustible backsplash can be used.
SIDE VIEW WITH A BACKSPLASH
Locate gas and electric as shown
GAS SUPPLY
The natural gas models are designed to operate at
5" water column pressure. For proper operation, the
pressure of the natural gas supplied to the regulator
must be between 7" and 13" water column.
The LP models are designed to operate at 10" water
column pressure. For proper operation, the pressure
of the LP gas supplied to the regulator must be
between 11" and 13" water column.
UNIVERSAL UTILITY LOCATIONS