Installation Instructions

13




The pressure regulator and burner orifices are set
for natural gas. To use LP gas, the regulator and
burner orifices must be converted. The LP orifice
spuds for the cooktop burners can be located in the
literature package attached to the regulator.
 The cooktop, as shipped from
the factory, is set for use with natural gas. If you
wish to use your cooktop with LP gas, you must
first replace the orifices and convert the pressure
regulator.
This conversion must
be performed by a qualified installer or gas supplier
in accordance with the manufacturer’s instructions
and all codes and requirements of the authority
having jurisdiction. Failure to follow instructions could
result in serious injury or property damage. The
qualified agency performing this work assumes
responsibility for the conversion.
The following adjustments
must be made before turning on the burner.
Failure to do so could result in serious injury. Be
sure pressure regulator has been converted as
described in Step 2.


Disconnect all electrical power, at the main
circuit breaker or fuse box.
Shut off the gas supply to the cooktop
by closing the manual shut-off valve.
Adjust the pressure regulator, by the following
instructions:
Unscrew the cap.
Place your thumb against the flat side of the
spring retainer and press down to remove
the retainer.
Carefully look at the spring retainer to locate
the NAT or LP position.
Turn the spring retainer over so that
LP is showing on the bottom.
Snap the retainer back into position.
Screw the cap back onto the regulator.
DOWN
FOR OFF
NAT
LP
LP
NAT
LP
NAT
NAT
LP
Gasket
Cap
Spring
Retainer
L.P./Propane
Position
NAT.
Position
Pressure Regulator


Safety Glasses
Small Flat-Head
Screwdriver (4mm or
5/32” tip size, 60mm
long)
Phillips- Head
Screwdriver
Pliers
7mm Nutdriver
No. 15 Torx-Head
Driver

If you wish to use this product
with Liquefied Petroleum (LP) gas containing greater
than 10% butane, you must purchase a butane
conversion kit. To order,
please call 1.888.664.8403 or 1.787.276.4051.
Model Butane Kit #
JGP970 WB28T10229
ZGU36 WB28T10229
JGP975 WB28T10231
JGP963 WB28T10233
JGP630 WB28T10235
JGP628 WB28T10236