Specifications
ZGU486NDPSS (Natural Gas)
Monogram
48" Professional Gas Rangetop with 6 Burners and Griddle
Product Specification Revised 1/16
For answers to your Monogram, GE Café
™
Series, GE Profile
™
Series
or GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Dimensions and Installation Information
Backsplash Accessories
The rangetop requires a 12" minimum clearance to a
vertical combustible surface at the rear. A backsplash
is required for installations with less than 12" clearance.
The following backsplash accessories are available, or a
custom, non-combustible backsplash can be used.
ZX12B48PSS, 12" backsplash
ZXADJB48PSS, 30"-36" adjustable-height backsplash with
warming shelf
Backsplash with Warming Shelf
All Monogram Professional Hoods feature infrared warming
lights. The 30"-36" adjustable backsplash with warming
shelf is a perfect complement when installed with the
tapered or straight-sided hoods.
• Restaurant-Style Professional Hoods are shipped with a
22" stainless steel backsplash and warming shelf.
Side View with a Backsplash
Advance Planning for 48"
Professional Rangetops
Professional rangetops offer a number of choices in size and
rangetop configurations.
• All professional rangetops are factory set for natural gas.
Conversion orfices for liquid propane are packed with
product.
High Altitude kit, WB28K10553, is also available.
The kits must be installed by a qualified service technician
at additional cost.
Electrical Requirements
Rangetops must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15 amp circuit breaker or time-delay fuse.
Gas Supply
• Natural gas models are designed to operate at 5" water
column pressure. For proper operation, the pressure of the
natural gas supplied to the regulator must be between 7"
and 13" water column.
• If converted to liquid propane, the models are designed
to operate at 10" water column pressure. For proper
operation, the pressure of the LP source to the regulator
must be between 11" and 13" water column.