Retrofit Quick Specification

Product Specication Revised 6/20
HELPFUL TIPS
C
A minimum 3 1/2" (8.9) nished return matching
cabinet exterior recommended on interior on all sides
and top at front of opening
In a side-by-side installation of a left-and-right-hand
door swing product, minimum 1/2" clearance between
the units is required. Also required is Side-by-Side
Heater/Dual Installation Kit, ZKUN, 42" trim kit,
ZKR42N and 42" stainless toekick ZKK42P.
For retro fit installations, both units can be plugged into
the same electrical supply receptacle.
PAGE 1 OF 8
For questions about your
appliance, please call 1-800-626-2000.
FRONT VIEW
SIDE VIEW
W
24" (61.0)
2"
(5.1)
4 3/4"
(12.1)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
E
WATER
41 1/2" (105.4)
18" (45.7)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5)
From floor
to bottom
of electrical
area
6"
(15.2)
5"
(12.7)
5"
(12.7)
5"
(12.7)
ZISP420DXSS
SIDE VIEW INSTALLED
UNDER SOFFIT
SOFFIT
SIDE VIEW INSTALLED
WITH WOODEN WALL STUDS
AND NO SOFFIT
FRONT VIEW INSTALLED
WITH METAL WALL STUDS
AND NO SOFFIT
*84"
(213.4)
*Or installation
height from floor
2" x 4"
Cut to 35" Length
Screws mounted
into vertical wall
studs
Top Case Trim
3/4"
Min.
Side View Top
Case Trim
Install Screws
Through Trim and Into
3/4" Min. Wood Brace
The refrigerator will project forward, slightly beyond adjacent cabinetry.
STANDARD INSTALLATION
SIDE VIEW
24" (60.9)
COLUMNS RETROFIT
3 1/2"
(8.9)
Finished
Return
Back
3/4"
(1.91)
W
SIDE VIEW
24" (60.9)
COLUMNS RETROFIT
3 1/2"
(8.9)
Finished
Return
Back
3/4"
(1.91)
W
MONOGRAM 42" BUILT-IN
COLUMNS RETROFIT
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp supply is
recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
C
WARNING:
When installing appliance, you must use and follow
the product installation instructions. These can be
found with unit or on web at monogram.com.