Specifications
Product Specification Revised 1/18
STANDARD INSTALLATION
ANTI-TIP BRACKET
ZIPP360NHSSMONOGRAM 36" BUILT-IN FRENCH-DOOR BOTTOM-FREEZER
35 1/2" (90.2)
2 5/16"
(5.9)
24" (61.0)
2"
(5.1)
4 13/16"
(12.2)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
6"
(15.2)
10"
(25.4)
5"
(12.7)
5"
(12.7)
WATER
ZIPP360NZ
ELEC.
W
SIDE VIEWFRONT VIEW
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
A
Mounting the junction
box in this location
will also allow for front
accessibility through
access panel.
B
Water supply area
WARNING:
The refrigerator is top heavy
and must be secured to
prevent the possibility of
tipping forward. Failure to
do so may result in death or
serious injury.
The information below is for
cabinet design only. When
installing the anti-tip system
you must use the product
installation instructions.
The information below
applies to all installation
constructions:
• A wall bracket, bolts and
toggles will be supplied
with the unit.
• The bolts will be used to
attach bracket to wall in
4 locations. Two of the
locations must penetrate
the center of the wall
studs.
• The toggles are used for
stability in drywall and
when metal studs are
encountered. Lag bolts are
used in wood studs.
• In installation opening,
measure 81-1/2" from
floor and draw a horizontal
line.
• Locate and mark the wall
studs on horizontal line.
Verify at least two studs
have their centerlines
within the center 32-1/2"
of installation opening to
ensure 2 wall studs are
penetrated.
• The bracket will be centered
left to right in opening with
bottom of bracket on the
horizontal line.
• When unit is placed in
opening, the bracket tabs
will align with openings
in back of the unit. The
unit will be secured to the
bracket using supplied
“L” bolts.
See Installation Instructions
for detailed instructions.
A
B
24" (61.0)
1 1/2"
(3.8)
3"
(7.6)
7/16"
(1.1)
Trim overlap
35 1/2" (90.2)
2 5/16"
(5.9)
SIDE VIEWFRONT VIEW
ZIC360NXRH
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10"(25.4)
Use two
additional hole
locations at end
of brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
24" (61.0)
1 1/2"
(3.8)
3"
(7.6)
7/16"
(1.1)
Trim overlap
35 1/2" (90.2)
2 5/16"
(5.9)
SIDE VIEWFRONT VIEW
ZIC360NXRH
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10"(25.4)
Use two
additional hole
locations at end
of brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
NOTES