Specification Sheet
For questions about your
appliance, please call 1-800-626-2000.
PAGE 12 OF 17 Product Specication Revised 10/20
Trimmed refrigerators are designed
to be customized with decorative
panels. Field-installed 1/2" or 3/4"
custom door and grille panels are
required. For 3/4" raised panels,
routing is required. e router depth
is 1/4" all the way around the panel’s
backs. Additional panel width
reductions are required per the
diagrams shown. is will create
“picture frame” routing allowing the
panels to slide into the attached door
and grille trims.
Maximum total panel weight:
• Door panel – 67 lbs.
• Grille panel – 11 lbs
Note: For panels constructed with rails
and stiles (5-panel), the rails must be a
minimum of 3" wide and stiles must be
a minimum of 4" wide.
Door Handles:
Custom handles are required for flush
installation.
Order a ZKBFN720NII unification
kit for an integrated appearance on
2 custom panel models installed
side-by-side.
TOP
FrontBack
BOTTOM
3/4" PANEL SIDE VIEW
(AFTER ROUTING)
3/4"
11/32"
1/4"
1/4"
1/4"
7/16"
DETAIL TOP
DETAIL BOTTOM
DETAIL
LEFT SIDE
DETAIL RIGHT
SIDE
2-1/16"
2-1/16"
ROUTER DEPTH 1/4" ROUTER DEPTH 1/4"
1/4"
3/32"
3/4" PANEL BOTTOM VIEW
(AFTER ROUTING)
LEFT
SIDE
RIGHT
SIDE
Front
Back
Front
NOTE: Routed areas should
be finished as they may be
visible when assembled.
CORNER VIEW SHOWING
“PICTURE FRAME” ROUTING
Back
FLUSH INSET
INSTALLATION
HELPFUL TIPS