User Manual

Performance Data Information
&DSDFLW\*DOORQV/LWHUV
7KHFRQFHQWUDWLRQRIWKHFRQWDPLQDQWVWHVWHGIRUWKLV¿OWHULQZDWHUHQWHULQJWKHV\VWHPZDVUHGXFHG
to a concentration less than or equal to the permissible limit for water leaving the system as speci-
¿HGLQ16)$16,6WDQGDUGDQG6WDQGDUG6\VWHPWHVWHGDQGFHUWL¿HGE\16),QWHUQDWLRQDO
against NSF/ANSI Standard 42 and Standard 53.
Please see geappliances.com for complete listing of the contaminants tested and the amounts
reduced.
26
The following pharmaceutical reduction claims have not been certified by NSF International or the state of California.
Claims tested and verified by independent laboratory:
Contaminant
Reduction
Average
Influent
NSF specified
Challenge
Concentration
Avg %
Reduction
Average
Product Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduction
Requirements
NSF
Test Report
Atenolol 978 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121587
Fluoxetine 907 ng/l N/A 99.4% 5.4 ng/L N/A N/A J-00121587
Ibuprofen 885 ng/L N/A 94.1% 52.3 ng/L N/A N/A J-00121588
Progesterone 1097 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121589
Trimethoprim 415 ng/L N/A 99.5% 2.0 ng/L N/A N/A J-00121587
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as
advertised. See Installation Manual for Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (21.9 lpm)
Water Supply Potable Water
Water Pressure 40-120 psi (2.8-8.2 bar)
Water Temperature 33°F-100°F (0.6°C-38°C)
Note: While the testing was performed under standard laboratory
conditions, actual performance may vary. Contaminant reduction
testing is conducted every five years by certifying agency to
maintain certification.
Replacement Cartridge: MWF. For estimated costs of replacement
elements please call 1.877.959.8688 or visit our website at
www.geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before and
after the system. Systems certified for cyst reduction may be
used on disinfected water that may contain filterable cysts.
NOTICE
To reduce the risk associated with property damage due to
water leakage:
Read and follow use instructions before installation and use of
this system.
• Installation and use MUST comply with all state and local
plumbing codes.
Do not install if water pressure exceeds 120 psi (8.2 bar). If your
water pressure exceeds 80 psi, you must install a pressure-
limiting valve. Contact a plumbing professional if you are
uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If
water hammer conditions exist you must install a water hammer
arrester. Contact a plumbing professional if you are uncertain
how to check for this condition.
Do not install on hot water supply lines. The maximum operating
water temperature of this filter system is 100º F (38º C).
Protect filter from freezing. Drain filter when temperatures drop
below 33ºF (0.6ºC).
• The disposable filter cartridge should be replaced every 6
months at the rated capacity, or sooner if a noticeable reduction
in flow rate occurs.
REPLACEMENT
ELEMENT
Tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 in model
GE Appliances MWF for the reduction of the
claims specified on the performance data sheet.
Performance Data Sheet
SmartWater
Filtration SystemGE Appliances MWF Cartridge