Quick Specs

Grille
OPTIONAL ACCESSORIES
FILTER KIT
JX81D–RECIRCULATING CHARCOAL
FILTER KIT
To be used when the Advantium oven
cannot be vented to the outside.
FILLER PANEL KITS JX36B
When replacing a 36" range hood, this kit
fills in the additional width to provide a
custom built-in appearance. For installation
between cabinets only; not for end-of-
cabinet installation. Each kit contains two
3"-wide filler panels.
Duct EQUIVALENT
Rectangular-To-Round
Transition Adaptor
5 Ft.
Wall Cap 40 Ft.
90° Round Elbow 10 Ft.
45° Round Elbow 5 Ft.
90° Rectangular Elbow 25 Ft.
45° Rectangular Elbow 5 Ft.
Roof Cap 24 Ft.
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Revised 10/20
HELPFUL TIPS
PAGE 3 OF 3
HOOD EXHAUST DUCT
Outside ventilation requires a
hood exhaust duct. Read the
following carefully.
EXHAUST CONNECTION:
e hood exhaust has been designed
to mate with a standard 3-1/4" x 10”
rectangular duct.
If a round duct is required, a
rectangular-to-round transition
adaptor must be used. Do not
use less than a 6" diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to
be used, care should be taken to align
exhaust with the space between studs,
or wall should be prepared at the time
it is constructed by leaving enough
space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the
total duct length of 3-1/4" x 10"
rectangular or 6" diameter round duct
should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS,
WALL AND ROOF CAPS, etc.,
present additional resistance to airflow
and are equivalent to a section of
straight duct which is longer than their
actual physical size. When calculating
the total duct length, add the equivalent
length of all transitions and adaptors
plus the length of all straight duct
sections. e chart below shows the
approximate feet of equivalent
length of some typical ducts.