Owner`s manual

7
Advance Planning
DUCT FITTINGS
Equivalent Quantity Total
Duct Piece Length* Used Length
10"round
to8"round 5ft.
Round, 1 ft.
straight (perfootlength)
8"Dia.17ft.
90°elbow 10"Dia.24ft.
8"Dia.10ft.
45°elbow 10"Dia.14ft.
Round 8"Dia.32ft.
wallcap 10"Dia.41ft.
with damper
Round 8"Dia.44ft.
roofcap 10"Dia.56ft.
Usethischarttocomputemaximum
permissable lengths for duct runs to
outdoors.
Forbestresults,use10"diameterduct.
Note: Do not exceed maximum permissable
equivalent lengths!
Maximum recommended duct
length for these hoods: 150 feet
Flexible ducting:
Ifexiblemetalductingisused,all
the equivalent feet values in the table
shouldbedoubled.Theexiblemetal
duct should be straight and smooth
andextendedasmuchaspossible.
DoNOTuseexibleplasticducting.Note:
Any home ventilation system, such as a ventilation
hood, may interrupt the proper ow of combustion
air and exhaust required by replaces,
gas furnaces, gas water heaters and other natu-
rally vented systems. To minimize the chance of in-
terruption of such naturally vented systems, follow
the heating equipment manufacturer’s guidelines
and safety standards such as those published by
NFPA and ASHRAE.
TotalDuctRun
Hoods Are Equipped
For 10" Round Duct
*Hoodsaresuppliedwitha10"round
transition. A locally
supplied transition is required
for other sizes.
Note: Outlet on top of hood is
8-1/8"x8".
*Actual length of straight duct plus duct
ttingequivalent.Equivalentlengthofductpieces
are based on actual tests conducted
byGEEvaluationEngineeringandreectrequire-
ments for good venting performance with any
ventilation hood.