Installation Instructions

ZV750/ZV755 Installation Heights
Upper (Inner) Duct Cover (B) 24.25
Lower (Outer) Duct Cover (A) 18.5
Accessory Lower (Outer) Duct Cover (A) 31.5
Actual *VENTED *RECIRCULATING
Ceiling Installation Installation
Height Height Height
711 24to 28 24to 28
8 0 24 to 29 24 to 29
8 1 24 to 30 24 to 30
8 2 24 to 30 24 to 30
83 24 to 30 24 to 30
8 4 24 to 30 24 to 30
8 5 24 to 30 24 to 30
8 6 24 to 30 24 to 30
8 7 24 to 30 24 to 30
8 8 24 to 30 24 to 30
8 9 25 to 30 24 to 30
8 10 26 to 30 24 to 30
8 11 27 to 30 24 to 30
9 0 28 to 30 24 to 30
9 1 29to 30 25 to 30
9 2 30 26 to 30
9 3 27 to 30
9 4 28 to 30
9 5 29 to 30
9 6 30
9 0 24 to 30 24 to 28
9 1 24 to 30 24 to 29
9 2 24 to 30 24 to 30
9 3 24 to 30 24 to 30
9 4 24 to 30 24 to 30
95 24 to 30 24 to 30
9 6 24 to 30 24 to 30
9 7 24 to 30 24 to 30
9 8 24 to 30 24 to 30
9 9 24 to 30 24 to 30
9 10 25 to 30 24 to 30
9 11 26 to 30 24 to 30
10 0 27 to 30 24 to 30
10 1 28 to 30 24 to 30
10 2 29 to 30 24 to 30
10 3 30 25 to 30
10 4 26 to 30
10 5 27 to 30
10 6 28 to 30
10 7 29 to 30
10 8 30
*Based on 36 countertop height.
Installation Preparation
DETERMINE INSTALLATION HEIGHT
Telescopic duct covers are provided to conceal
the ductwork running to the ceiling.
This hood can be installed for vented or
recirculating operation. All necessary parts are
shipped with the hood.
NOTE: Installation height should be measured from
the cooking surface to the bottom of the hood.
The vent hood must be installed 24 min. and
30 max. above the cooking surface. The hood
installation height, from the cooking surface to the
bottom of the hood, depends upon ceiling height
and duct cover limitations.
DUCT COVER DIMENSIONS
ZX7510SPSS Duct Cover Accessory
This accessory is available for installation with
ceiling heights above 9 feet to 10 feet and higher.
This accessory consists of one 31-1/2lower duct
cover.
ACCESSORY ZX90010 SUPPLIED
ZX7510SPSS (Need Accessory Lower Duct Cover 31.5)
8
9-1/4
11-7/8