CABINET REQUIREMENTS
This hood may be installed beneath a wall-mounted
cabinet.
Both vented and recirculating operation can be
accomplished in an under-cabinet installation.
If the cabinet has been installed, it must be removed so
that wall framing supports can be added.
The cabinet must be at least 20" high between the
bottom frame and the inside top. A custom cabinet or
modifications to a dierent size cabinet may be required
to accommodate the hood housing.
• The cabinet must be 36" wide.
The cabinet must be rmly secured to wall studs or
the added framing support and capable of supporting
100 pounds.
DUCTWORK, WIRING
• Determine the exact location of the vent hood.
Locate the Rear Wall Template packed with the
literature.
Measure 36" from the oor to the top of the cooking
surface. Add the pre-determined hood installation
height. Mark that location.
• Use a level to draw a straight pencil line on the wall.
Tape the template in position along the penciled line.
Check to be sure the template is level.
Use the level to draw a line straight up, from the
centerline on the template to the ceiling.
Measure 3-3/34" from the back wall to the centerline
of a 6-1/2" hole on the ceiling.
NOTE
If drywall is not present, add drywall thickness to the
3-3/4" dimension.
HOUSE WIRING LOCATION
The junction box is located on the top right side
of the hood.
Wiring should enter the back wall 20" to 26" above
the bottom of the hood, and within 4" of the right
side of the centerline. Wiring should enter at least
4" above the bracket on the right side.
24” Min.
30” Max.
20” Min.
19-1/2”
11-3/4”
11”
REAR WALL TEMPLATE
C
L
49-80271 JR 07-04
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
Drill 1/8"
Pilot Holes
ALIGN BOTTOM EDGE WITH
PENCIL LINE INDICATING
BOTTOM OF THE HOOD.
5-1/16"
9-5/8"
8-1/8"
2-1/16"
13-3/4"
12-3/4"
Ceiling
3-3/4” centerline
to wall