Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Ŷ IMPORTANT — Save these instructions for local inspector’s use. IMPORTANT — Observe all governing codes and ordinances. Ŷ Note to Installer — Be sure to leave these instructions with the Consumer. Ŷ Note to Consumer — Keep these instructions with your Owner’s Manual for future reference. Ŷ Skill Level — Installation of this appliance requires basic mechanical and electrical skills.
Design Information CONTENTS Design Information 3URGXFW 'LPHQVLRQV DQG &OHDUDQFHV ............................ 3 Installation Options ........................................................ 3 ,QVWDOODWLRQ 3UHSDUDWLRQ $GYDQFH 3ODQQLQJ 'XFWZRUN )UDPLQJ ......................... 4 3RZHU 6XSSO\ ................................................................ 4 'XFW )LWWLQJV .................................................................. 5 Tools and Materials Required .......................................
Installation Preparation ADVANCE PLANNING POWER SUPPLY Ŷ 'HWHUPLQH WKH H[DFW ORFDWLRQ RI WKH YHQW KRRG IMPORTANT - (Please read carefully) Ŷ 3ODQ WKH URXWH IRU YHQWLQJ H[KDXVW WR WKH RXWGRRUV Ŷ 8VH WKH VKRUWHVW DQG VWUDLJKWHVW GXFW URXWH SRVVLEOH )RU VDWLVIDFWRU\ SHUIRUPDQFH GXFW UXQ VKRXOG QRW H[FHHG IW HTXLYDOHQW OHQJWK IRU DQ\ GXFW configurations. Ŷ 5HIHU WR ³'XFW )LWWLQJV´ FKDUW WR FRPSXWH WKH PD[LPXP SHUPLVVLEOH OHQJWK IRU GXFW UXQV WR WKH outdoors. Ŷ :KHQ DSSOLFDEOH LQVWDOO DQ\
Installation Preparation DUCT FITTINGS This Hood Must Use an 8” Round Duct. It Can Transition to a 3-1/4” x 12” Duct. 8VH WKLV FKDUW WR FRPSXWH PD[LPXP SHUPLVVLEOH OHQJWKV for duct runs to outdoors. NOTE: 'R QRW H[FHHG PD[LPXP SHUPLVVLEOH HTXLYDOHQW lengths! Maximum duct length: 100 foot for range hoods. Duct Piece Dimensions Equivalent Length* 5RXQG straight 1 ft. (per foot length) ´ [ ´ straight 1 ft.
Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) Ŷ Tape measure Ŷ Knife Ŷ Spirit level Measuring tape Ŷ :LUH FXWWHU VWULSSHU Ŷ :LUH QXWV Ŷ Electric drill with 5/16” and 3/8” bits Ŷ 3KLOOLSV DQG IODW EODGH VFUHZGULYHUV Ŷ Hammer 3OLHUV Ŷ 3OLHUV Ŷ Safety glasses Ŷ Duct tape Ŷ Tape to mount template Ŷ *ORYHV WR SURWHFW DJDLQVW VKDUS HGJHV Ŷ 9 +] RU $PS ZLUH ZLWK Duct tape JURXQG 3URSHUO\ JURXQGHG EUDQFK FLUFXLW Ŷ Strain relief for junction cover Ŷ ´ URXQG PHWDO GXFW OHQJW
Installation Preparation DETERMINE INSTALLATION HEIGHT NOTE: Measure installation height from the cooking surface to the outer glass portion of the hood. 24” Min. ´ 0D[ 36” Min. 7KH YHQW KRRG PXVW EH LQVWDOOHG ´ PLQ DQG ´ PD[ DERYH WKH FRRNLQJ VXUIDFH 7KH KRRG LQVWDOODWLRQ KHLJKW IURP WKH FRRNLQJ VXUIDFH WR WKH ERWWRP RI WKH KRRG GHSHQGV XSRQ FHLOLQJ KHLJKW ACCESSORIES: Ŷ 2UGHU =; DFFHVVRU\ IRU =9 ZDOO PRXQW KRRG WR UHDFK FHLOLQJ KHLJKWV EHWZHHQ ¶ ´ DQG ¶ ´ 7KLV DFFHVVR
Installation Preparation CHECK INSTALLATION HARDWARE /RFDWH WKH KDUGZDUH DFFHVVRU\ ER[ SDFNHG ZLWK WKH KRRG DQG FKHFN FRQWHQWV +$5':$5( 3$&.
Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE DUCTWORK, WIRING LOCATIONS 'HWHUPLQH WKH H[DFW ORFDWLRQ RI WKH YHQW KRRG Ŷ /RFDWH WKH WHPSODWH SDFNHG ZLWK WKH OLWHUDWXUH ± 0HDVXUH ´ IURP WKH IORRU WR WKH WRS RI WKH FRRNLQJ VXUIDFH $GG KRRG LQVWDOODWLRQ KHLJKW GHWHUPLQHG RQ SDJH 0DUN WKDW ORFDWLRQ ± 8VH D OHYHO WR GUDZ D VWUDLJKW SHQFLO OLQH RQ WKH wall.
Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 2 INSTALL MOUNTING BRACKET This vent hood must be secured to the horizontal support or wall studs. Ŷ :LWK WKH WHPSODWH WDSHG LQ SODFH XVH D SXQFK WR mark mounting bracket screw locations. Ŷ 'ULOO ´ SLORW KROHV LQ RI WKH SXQFKHG ORFDWLRQV in the lower bracket. 3 INSTALL DUCT BRACKET The duct bracket should be installed against the back wall and flush with the ceiling. This bracket will hold the duct cover in place at the top.
Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 4 PREPARE THE HOOD Ŷ 3ODFH WKH KRRG RQ D SDGGHG VXUIDFH Carefully lay the hood on its back. Ŷ 3RVLWLRQ WKH PRWRU KRXVLQJ DW WKH EDFN RI WKH KRRG (OHFWULFDO FRQQHFWRUV VKRXOG IDFH WKH IURQW ZLWK UHDU mounting hooks at the back. Ŷ )DVWHQ WKH KRRG WR WKH PRWRU KRXVLQJ IURP WKH ERWWRP using 6 screws. )URQW VLGH Ŷ 6OLS WKH ERWWRP IODQJH RI WKH PRWRU KRXVLQJ LQWR WKH side slots at the top rear opening.
Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 5 MOUNT THE HOOD WARNING 2 people are required to lift and position the hood onto the mounting bracket. AVERTISSEMENT ,I IDXW GHX[ SHUVRQQHV SRXU lever et mettre en place la hotte sur le support de montage. 7 CONNECT DUCTWORK Ŷ ,QVWDOO GXFWZRUN PDNLQJ FRQQHFWLRQV LQ WKH GLUHFWLRQ of airflow as illustrated.
Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 8 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING If house wiring is not 2-wire with a JURXQG ZLUH D JURXQG PXVW EH SURYLGHG E\ WKH LQVWDOOHU :KHQ KRXVH ZLULQJ LV DOXPLQXP EH VXUH WR XVH 8 / DSSURYHG DQWL R[LGDQW FRPSRXQG DQG DOXPLQXP WR copper connectors. Ŷ 6HFXUH WKH KRXVH ZLULQJ WR WKH MXQFWLRQ ER[ ZLWK a strain relief. House wiring - %R[ FRYHU AVERTISSEMENT Si le câblage de la maison n’est SDV GX W\SH j
Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 9 INSTALL DUCT COVERS Ŷ 3ODFH WKH GHFRUDWLYH GXFW covers on top of the hood. NOTE: The inside (upper) duct piece has holes on one end. The holes are intended for use when the hood is installed for recirculating purposes. Slide the inside end into the outer piece; the vent holes should not be visible in this installation.
Installation Instructions INSTALLATION—RECIRCULATING DUCTWORK, WIRING LOCATIONS 'HWHUPLQH WKH H[DFW ORFDWLRQ RI WKH YHQW KRRG Ŷ /RFDWH WKH WHPSODWH SDFNHG ZLWK WKH OLWHUDWXUH Ŷ 0HDVXUH ´ IURP WKH IORRU WR WKH WRS RI WKH FRRNLQJ VXUIDFH $GG KRRG LQVWDOODWLRQ KHLJKW GHWHUPLQHG RQ SDJH 0DUN WKDW ORFDWLRQ Ŷ 8VH D OHYHO WR GUDZ D VWUDLJKW SHQFLO OLQH RQ WKH ZDOO 1 INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT — )UDPLQJ PXVW EH FDSDEOH RI VXSSRUWLQJ OEV View from rear cleats Ceiling ´ [ ´
Installation Instructions INSTALLATION—RECIRCULATING 2 INSTALL MOUNTING BRACKET This vent hood must be secured to the horizontal support or wall studs. Ŷ :LWK WKH WHPSODWH WDSHG LQ SODFH XVH D SXQFK WR mark mounting bracket screw locations. Ŷ 'ULOO ´ SLORW KROHV LQ RI WKH SXQFKHG ORFDWLRQV in the lower bracket. 3 INSTALL DUCT BRACKET The duct bracket should be installed against the back wall and flush with the ceiling. This bracket will hold the duct cover in place at the top.
Installation Instructions INSTALLATION—RECIRCULATING 4 PREPARE THE HOOD 5 MOUNT THE HOOD Ŷ 3ODFH WKH KRRG RQ D SDGGHG VXUIDFH Ŷ 3RVLWLRQ WKH PRWRU KRXVLQJ DW WKH EDFN RI WKH KRRG (OHFWULFDO FRQQHFWRUV VKRXOG IDFH WKH IURQW ZLWK UHDU mounting hooks at the back. Ŷ 6OLS WKH ERWWRP IODQJH RI WKH PRWRU KRXVLQJ LQWR WKH side slots at the top rear opening. WARNING 2 people are required to lift and position the hood onto the mounting bracket.
Installation Instructions INSTALLATION—RECIRCULATING 7 SIZE AND CUT DUCT PIECE 8 CONNECT ELECTRICAL Ŷ +ROG XSSHU DLU GHIOHFWRU ZLWK GXFW FRQQHFWRU DJDLQVW the ceiling. Ŷ 0HDVXUH IURP WKH ERWWRP RI WKH DLU GHIOHFWRU WR WKH top of the hood as shown. Reduce that dimension by 1” to facilitate installation. The duct will cover and overlap the deflector and the hood outlets. Verify that power is turned off at the source.
Installation Instructions INSTALLATION—RECIRCULATING 9 INSTALL DUCT COVERS Ŷ 3ODFH WKH GHFRUDWLYH GXFW covers on top of the hood. NOTE: The inside piece has holes on one end intended for use when the hood is installed for recirculating purposes. Be sure the vented end is at the top; the vent holes will be visible in this installation.
NOTE: :KLOH SHUIRUPLQJ LQVWDOODWLRQV GHVFULEHG LQ WKLV ERRN safety glasses or goggles should be worn. )RU 0RQRJUDP® ORFDO VHUYLFH LQ \RXU DUHD YLVLW monogram.com. NOTE: 3URGXFW LPSURYHPHQW LV D FRQWLQXLQJ HQGHDYRU DW 0RQRJUDP $SSOLDQFHV 7KHUHIRUH PDWHULDOV DSSHDUDQFH and specifications are subject to change without notice. 49-80328 Rev.