Installation Guide
49-80328 Rev. 4
Installation Instructions
DUCTWORK, WIRING LOCATIONS
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ/RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH
±0HDVXUH´IURPWKHIORRUWRWKHWRSRIWKH
FRRNLQJVXUIDFH$GGKRRGLQVWDOODWLRQKHLJKW
GHWHUPLQHGRQSDJH0DUNWKDWORFDWLRQ
±8VHDOHYHOWRGUDZDVWUDLJKWSHQFLOOLQHRQWKH
wall.
±7DSHWKHWHPSODWHLQSRVLWLRQDORQJWKH
penciled line. CHECK TO BE SURE THE
7(03/$7(,6/(9(/
Ceiling ducting:
,IGXFWZRUNZLOOYHQWVWUDLJKWXSWRWKHFHLOLQJ
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template to the ceiling.
Ŷ0HDVXUH´IURPWKHEDFNZDOOWRWKHFHQWHUOLQH
of an 8-1/2” hole on the ceiling.
NOTE:,IGU\ZDOOLVQRWSUHVHQWDGGGU\ZDOOWKLFNQHVV
to the 5-1/2” dimension.
Wall Ducting:
,IGXFWZRUNZLOOYHQWWRWKHUHDU
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template.
Ŷ0HDVXUHDWOHDVW´DERYHWKHSHQFLOOLQHWKDW
LQGLFDWHVWKHERWWRPLQVWDOODWLRQKHLJKWWRWKH
centerline of an 8-1/2” dia. duct hole. (Hole may be
elongated for duct elbow.)
HOUSE WIRING LOCATION:
Ŷ7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI
the hood.
Ŷ:LULQJVKRXOGHQWHUWKHEDFNZDOODWOHDVW´DERYH
WKHERWWRPRIWKHKRRGDQGZLWKLQ´RIWKHOHIWVLGH
of the centerline.
5-1/2” c enterline to wall
8-1/2” dia. hole
)25&(,/,1*9(17'8&7,1*
Centerline 26” above the
marked bottom pencil line
for installation height.
)25:$//9(17'8&7
Ceiling
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT — )UDPLQJPXVWEHFDSDEOHRI
VXSSRUWLQJOEV
,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU
the top mounting brackets. Remove the template.
Ŷ&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
Ŷ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW´[´EHWZHHQ
two wall studs at the bottom mounting bracket
installation location. The horizontal support must
be flush with the room side of the studs. Use cleats
behind both sides of the support to secure to wall
studs.
Ŷ5HLQVWDOOGU\ZDOO
Centerline of
installation
space
View from
rear cleats
´[´PLQ
mounting
support
8-1/2” min. opening for ductwork
INSTALLATION—VENTED TO THE OUTSIDE