Installation Instructions
DUCTWORK, WIRING LOCATIONS
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ/RFDWHWKHWHPSODWHSDFNHGZLWKWKHOLWHUDWXUH
±0HDVXUH´IURPWKHIORRUWRWKHWRSRIWKH
FRRNLQJVXUIDFH$GGKRRGLQVWDOODWLRQKHLJKW
GHWHUPLQHGRQSDJH0DUNWKDWORFDWLRQ
±8VHDOHYHOWRGUDZDVWUDLJKWSHQFLOOLQHRQWKH
wall.
±7DSHWKHWHPSODWHLQSRVLWLRQDORQJWKH
penciled line. CHECK TO BE SURE THE
7(03/$7(,6/(9(/
Ceiling ducting:
,IGXFWZRUNZLOOYHQWVWUDLJKWXSWRWKHFHLOLQJ
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template to the ceiling.
Ŷ0HDVXUH´IURPWKHEDFNZDOOWRWKHFHQWHUOLQH
of an 8-1/2” hole on the ceiling.
NOTE:,IGU\ZDOOLVQRWSUHVHQWDGGGU\ZDOOWKLFNQHVV
to the 5-1/2” dimension.
Wall Ducting:
,IGXFWZRUNZLOOYHQWWRWKHUHDU
Ŷ8VHDOHYHOWRGUDZDOLQHVWUDLJKWXSIURPWKH
centerline on the template.
Ŷ0HDVXUHDWOHDVW´DERYHWKHSHQFLOOLQHWKDW
LQGLFDWHVWKHERWWRPLQVWDOODWLRQKHLJKWWRWKH
centerline of an 8-1/2” dia. duct hole. (Hole may be
elongated for duct elbow.)
HOUSE WIRING LOCATION:
Ŷ7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRI
the hood.
Ŷ:LULQJVKRXOGHQWHUWKHEDFNZDOODWOHDVW´DERYH
WKHERWWRPRIWKHKRRGDQGZLWKLQ´RIWKHOHIWVLGH
of the centerline.
5-1/2” c enterline to wall
8-1/2” dia. hole
)25&(,/,1*9(17'8&7,1*
Centerline 26” above the
marked bottom pencil line
for installation height.
)25:$//9(17'8&7
Ceiling
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT )UDPLQJPXVWEHFDSDEOHRI
VXSSRUWLQJOEV
,IGU\ZDOOLVSUHVHQWPDUNWKHVFUHZKROHORFDWLRQVIRU
the top mounting brackets. Remove the template.
Ŷ&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
Ŷ,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVW´[´EHWZHHQ
two wall studs at the bottom mounting bracket
installation location. The horizontal support must
be flush with the room side of the studs. Use cleats
behind both sides of the support to secure to wall
studs.
Ŷ5HLQVWDOOGU\ZDOO
Centerline of
installation
space
View from
rear cleats
´[´PLQ
mounting
support
8-1/2” min. opening for ductwork
INSTALLATION—VENTED TO THE OUTSIDE