:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions 30″, 36″ and 48″ Custom Hood Insert ZVC30LSS ZVC36LSS ZVC48LSS NET SPACE 49-80415 12-06 JR GE Monogram at ::rangehoods.
Installation Instructions WARNING: TO REDUCE THE RISK BEFORE YOU BEGIN OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
Installation Instructions AVERTISSEMENT : AFIN DE AVERTISSEMENT : RÉDUIRE LE RISQUE D’INCENDIE, DE CHOCS ÉLECTRIQUES OU DE BLESSURES CORPORELLES, VEUILLEZ VOUS CONFORMER AUX RECOMMANDATIONS SUIVANTES : A. L’installation et le câblage doivent être faits par une ou des personnes qualifiées et en conformité à tous les codes et normes applicables, y compris les normes en matière de coupe-feu. B.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Design Information CONTENTS Design Information Product Clearances ..........................................................................4 Product Dimensions ....................................................................5–7 Advance Planning Advance Planning ............................................................................8 Remote Mounting of the Control (Wired)..............................
Design Information PRODUCT DIMENSIONS Dimensions and Specifications (in inches) ZVC30 Outside Dimensions 27-1/2″ 14″ *Opening The Insert Sleeve The custom canopy must be sized to fit the insert sleeve. Construct the canopy with an opening that is: 26″W x 13-3/16″D The opening must be constructed of 3/4″ thick material to allow the sleeve locking clips to engage.
Design Information PRODUCT DIMENSIONS Dimensions and Specifications (in inches) ZVC36 Outside Dimensions 27-1/2″ 14″ *Opening The Insert Sleeve The custom canopy must be sized to fit the insert sleeve. Construct the canopy with an opening that is: 26″W x 13-3/16″D The opening must be constructed of 3/4″ thick material to allow the sleeve locking clips to engage.
Design Information PRODUCT DIMENSIONS Dimensions and Specifications (in inches) ZVC48 Outside Dimensions 39-1/2″ 14″ *Opening The Insert Sleeve The custom canopy must be sized to fit the insert sleeve. Construct the canopy with an opening that is: 38-3/4″W x 13-3/16″D The opening must be constructed of 3/4″ thick material to allow the sleeve locking clips to engage.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Advance Planning ADVANCE PLANNING POWER SUPPLY Ductwork Planning •This hood is equipped for 8″ round ductwork. •Determine the exact location of the vent hood. •Plan the route for venting exhaust to the outdoors. This hood is not designed for a recirculating venting operation. •Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 ft.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Advance Planning DUCT FITTINGS Use this chart to compute maximum permissible lengths for duct runs to outdoors. NOTE: Do not exceed maximum permissible equivalent lengths! Maximum duct length: 100 foot for 8″ round duct Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Preparation PARTS PROVIDED Locate the parts packed with the hood. CHECK INSTALLATION HARDWARE Hood liner (packed in separate carton) Count screws/ components. Screws shown actual size.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Wall Installation Preparation 5-1/2″ from rear wall to centerline DUCTWORK, WIRING LOCATIONS Determine the exact location of the insert sleeve. Mark the exact centerline location. The ceiling structure must be capable of supporting the weight of the insert sleeve (approximately 100 pounds) and any inadvertent user contact loads. • Measure from the top of the cooking surface to the bottom edge of the insert sleeve.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Island Installation Preparation CONSTRUCT CEILING SUPPORT (for Island Installation) Plan the Location of the Hood and Ductwork The ceiling structure must be capable of supporting the weight of the insert sleeve (approximately 100 pounds) and any inadvertent user contact loads. • Use a plumb bob to check the location. The countertop/cooktop below the insert sleeve must be centered with the insert sleeve.
Installation Preparation REMOTE MOUNTING OF THE CONTROL (WIRED) REMOTE LOCATION FOR CONTROL The control can be removed from the hood and installed in a backsplash or countertop. • A cover plate is provided to cover the opening in the hood when the control is removed. • A 30-ft. length of 4-wire cord is supplied to accommodate most installations. Because only 30-ft. of cord is provided, careful consideration must be given to the location of the remotely mounted control.
Installation Preparation REMOTE MOUNTING OF THE CONTROL (WIRED) (CONT.) WALL MOUNT COUNTERTOP Control 4-wire cord Wall bracket Connector Mounting plate Screws Mounting bracket Mounting bracket Screws Apply silicone around cutout opening Control Jack Mounting plate 4-wire cord 1. Cut out opening into the wall surface. Cutout dimensions are 1-11/16″ x 3-11/16″. 2. Loosen the 4 thumbscrews and remove the control from the insert sleeve. Replace the control with the blanking plate provided. 3.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions STEP 1 INSTALL HOOD LINER 1. Frame the cutout opening to fit the liner. NOTE: The opening support must be 3/4″ thick wood to accept the liner installation screws. 3. Secure the liner to the cabinet with 6 screws provided. 2. Slide the liner up and into the opening until flush with bottom edges. NET SPACE 16 GE Monogram at ::rangehoods.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions STEP 2 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, an electrician will need to convert existing wiring to meet these specs. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions STEP 3 INSTALL INSERT SLEEVE Aluminum tape 1. Tuck the house wiring out of the way. 2. Install the insert sleeve into the cutout opening of custom cabinet frame. 4. Align 8″ duct to exhaust opening of insert sleeve and seal with aluminum tape. NOTE: House duct should drop to 11-1/2″ above bottom edge of insert sleeve or the bottom of the 3/4″ cabinet base. Clip 3.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions STEP 4 INSTALL DAMPER PLATE Bolts 1. Pick up damper plate assembly and rotate so that vent side is up and bracket is located on left as you stand facing hood. 3. Secure damper plate assembly by placing nuts on bolts and tightening with socket or wrench. 2. Insert damper plate assembly into insert sleeve and carefully align with 8″ house duct. NET SPACE 19 GE Monogram at ::rangehoods.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions STEP 5 INSTALL BLOWER MOTOR 3. Place blower motor on damper plate assembly by sliding blower motor tabs into slots of damper plate assembly. 1. Pick up blower motor and rotate so tabs align with damper plate bracket. 2. Insert blower motor into insert sleeve through cutout opening of custom cabinet frame. 4.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions STEP 7 INSTALL FILTERS STEP 8 FINALIZE INSTALLATION 1. Remove protective film from the filters. 1. Check to be sure all tape and packaging materials have been removed. 2. Refer to Owner’s Manual for operating instructions. Clip 2. Tip the filter into the back tab slots and lift up. While maintaining slight backward pressure on filter, open clip and press into place with two hands.