INSTALLATION INSTRUCTIONS 36” and 48” Wall Hood ZVW1360, ZVW1480 Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet monogram.com. MONOGRAM.
Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT — Save these ■ instructions for local inspector’s use. IMPORTANT — Observe all governing ■ codes and ordinances. ■ Note to Installer – Be sure to leave these instructions with the Consumer. ■ Note to Consumer – Keep these instructions for future reference. ■ Skill level – Installation of this vent hood requires basic mechanical and electrical skills.
Installation Preparation PRODUCT DIMENSIONS 15” 23-5/8” 18” 36” 22” 36” Models Requires a 36” opening. 15” 35-5/8” 18” 22” 48” 48” Models Requires a 48” opening. 31-2000734 Rev.
Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) PLAN THE INSTALLATION CAUTION To reduce risk of fire and to properly exhaust air, be sure to duct the air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
Installation Preparation PARTS PROVIDED HARDWARE PACKAGE Locate the parts packed with the hood. Locate and check contents. A Top Damper Motor (2 with 48” model) (QTY: 4) 2.9mm x 6mm PZ screws. Used to attach the damper 761Dia28 Grease Drip Trays Hood Body Metal Installation Bracket B (QTY: 4) 8 x 1-3/4 AB screw. Used to mount the installation bar. Use 1/8” drill for pilot hole C D (QTY: 4 or 8) M4 screws. Used to mount motor (QTY:2) 3/16” dry wall anchors with screws.
Installation Preparation DUCT COVER REQUIREMENTS INSTALLATION DIMENSIONS Duct cover kits must be purchased separately. We recommend that the vent hood and duct cover (if used) be on site before final framing and wall finishing. This will help to accurately locate studs, ductwork and electrical service. The hood duct covers can be adjusted for different ceiling heights depending on the distance between the bottom of the hood and the cooktop (distance X). See Installation Height Table. 1” Min.
Installation Preparation INSTALLATION HEIGHT TABLE Ceiling Height (ft./in.) ZX8D13SPSS OR ZX8D14SPSS ZX10D13SPSS OR ZX10D14SPSS ZX12D13SPSS OR ZX12D14SPSS Ceiling Duct Cover up to 8 ft. High Ceiling Duct Cover up to 10 ft. High Ceiling Duct Cover up to 12 ft. Installation Over Gas Range Installation Over Electric Range Ceiling Height (ft./in.) 7’ 0” 24 7’ 1” 7’ 2” Installation Over Gas Range Installation Over Electric Range Ceiling Height (ft./in.
Installation Preparation ADVANCE PLANNING POWER SUPPLY Duct Install Planning IMPORTANT – (Please read carefully) ■ This hood is designed to be vented vertically through the ceiling with a 10” round duct or, horizontally through a wall with an 8”x12” duct transition and 12” round duct. ■ Use metal ductwork only. ■ Plan the route for venting exhaust to the outdoors. To maximize the ventilation performance of the vent system: 1. Minimize the duct run length and number of transitions and elbows. 2.
Installation Preparation NEW CONSTRUCTION, PRE-PLANNING, OR REMODELING NOTE: For existing instruction, skip to the next section. FOR TOP VENTING FOR BACK VENTING ■ For ducted installation through the top, the 10” diameter hole for the duct in the ceiling must be centered 6-1/4” away from the finished rear wall in the installation space.
Installation Preparation DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS •T his hood can be installed onto the wall or underneath the soffit. • For installing the hood to soffit, refer to page 12 for alternate mounting method. • A wall mounting template is included with the product for ease of installation. Follow the instructions below if the template is not being used.
Installation 1 I NSTALL HOOD SUPPORT 1 I NSTALL HOOD SUPPORT (Cont.) IMPORTANT: Framing must be capable of supporting 100 lbs for 36” models and 150 lbs for 48” models. •L ocate a minimum of 2 vertical studs for the installation bar by tapping drywall with a hammer or use a stud finder. •L evel the installation bar and center left to right above the marked line. Hold bar against the wall. • I nstall wall anchors (C) by tapping the anchors with a hammer to seat the teeth of the flanges into the wall.
Installation 3 I NSTALL HOOD ONTO WALL •P ull house wiring through knockout at the back or top of the hood. • Lift the hood and place over the hooks on the installation bar. Allow the hood to slide down into position. • Check to be sure the hood is level and centered. • Tighten wall anchor screws (C) to finish hood body installation to the wall. • Remove cover from junction box inside the hood.
Installation 4 ( Alternate Mounting Method) INSTALL HOOD TO SOFFIT (Cont.) •D rill two 1/8” pilot holes at a distance of 10-5/8” from the back wall in the horizontal wood supports. This is the vertical distance between mounting keyholes and back wall as shown in Figure C. • Drill two more 1/8” pilot holes at a distance of 2-1/2” from the back wall in the horizontal wood supports. This is the vertical distance between mounting screw holes and back wall as shown in Figure C.
Installation 6 C ONNECT ELECTRICAL Verify that power is turned off at the source. WARNING If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use UL approved anti-oxidant compound and aluminum-to-copper connectors. 7 C ONNECT DUCTWORK •C onnect the house ducting to the top damper as shown in Figure A.
Installation 8 I NSTALL DUCT COVERS •R efer to section “Duct Cover Requirements” on page 6 for duct cover accessory part numbers. •F ollow instructions included with the duct cover accessory to install duct covers. 9 I NSTALL GREASE TRAYS AND FILTERS •R emove protective film. • Place grease drip trays into slots. • Install the baffle filters. • Refer to the Use & 1 Care manual for further instructions to install grease drip trays and baffle filters.
NOTE: While performing installations described in this book, safety glasses or goggles should be worn. NOTE: Product improvement is a continuing endeavor at Monogram. Therefore, materials, appearance and specifications are subject to change without notice. 31-2000734 Rev.