INSTALLATION INSTRUCTIONS ZJ7000 and ZW9000 Electric Warming Drawer monogram.
Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Ŷ IMPORTANT — Save these instructions for local inspector’s use. Ŷ IMPORTANT — Observe all governing codes and ordinances. Ŷ Note to Installer — Be sure to leave these instructions with the Consumer. Ŷ Note to Consumer — Keep these instructions with your Owner’s Manual for future reference. Ŷ Completion Time — 1 to 3 hours. Ŷ Proper installation is the responsibility of the installer.
Design Information CONTENTS Design Information Models Available .......................................................3 Accessories ...............................................................3 Product Dimensions ..................................................4 Grounding the Appliance ..........................................5 Installation Instructions Step 1, Anti-Tip Brackets ..........................................9 Step 2, Install Warming Drawer ................................
Design Information PRODUCT DIMENSIONS AND CLEARANCES A 23-1/4” Drawer Open 1” C B Including Handle Models ZW9000 Dimensions A B C 22” 26” 30” ZW9000 w/ ZXD9030P 23-1/4” 27-1/2” 30” ZJ7000 22”26” 26-3/4” 27” Diminsions.
Design Information GROUNDING THE APPLIANCE Please read carefully. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances. This warming drawer must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse. Ŷ A properly grounded 3-prong receptacle should be located within reach of the drawers’ 56” long power cord.
Installation Preparation MATERIALS REQUIRED (provided) TOOLS REQUIRED 4 Wood Screws Hand Saw Drill and 1/16” Bit Safety Glasses Measuring Tape MATERIALS REQUIRED (not provided) Level Phillips Screwdriver Cut Resistant Gloves 2x2 or 2x4 Wood Block for Anti-Tip Security 2x2 or 2x4 Lumber for Runners Adhesive or other hardware for installing runners or shelf to support warmer drawer Runners must be level, rigidly mounted and capable of supporting 150 pounds.
Installation Preparation INSTALLATION OPTIONS Installation Below a Double Oven Installation Below a Single Oven 23-1/2” Min. Inside 23-1/2” Min. Inside 2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9” From Floor to Bottom of Block 2x2 or 2x4 Anti-Tip Block Against Rear Wall, 9” From Floor to Bottom of Block Oven Cutout Oven Cutout 2” Min. 9” 2” Min. Allow 5/8” Overlap on All Sides 9-1/4” Allow 5/8” Overlap on All Sides 23-1/4” 23-1/4” 9” 9-1/4” 10-1/2” A A B 1” Min.
Installation Preparation INSTALLATION BELOW A COUNTERTOP Electrical Outlet 16” Max. From Left Side Electrical Outlet Flush With Side of Cabinet 7” Max. 7” Install 2x4 or 2x2 Anti-Tip Block Against Rear Cabinet Wall 9” From Floor to Bottom of Block Electrical Outlet 42” Max. From Right Side 1-1/2” Cabinet Top 25” Install a Solid Barrier Below a Cooktop See Note 1” Min.* 9” 9-1/4” 36” Countertop Height A Dimensions Solid Barrier 23-1/2” Min.
Installation PROVIDE CABINET SUPPORT 2”x4” or Equivalent Runners 23-1/2” 2”x4” or Equivalent Runners 23-1/2” 22” 27” 25” 30” IMPORTANT: When installed below a single or double oven, check to be sure that any oven supports above the cutout do not obstruct the 23-1/2” required depth of the warming drawer cutout. Ŷ The support must be level and rigidly mounted, flush with the bottom edge of the cutout. – There is no way to level the drawer once it has been installed. Be sure supports are level.
Installation Instructions BEFORE YOU BEGIN Read these instructions completely and carefully. Ŷ IMPORTANT – Save these instructions for local inspector’s use. Ŷ Ŷ Ŷ Ŷ Ŷ Ŷ IMPORTANT – Observe all governing codes and ordinances. Note to Installer – Be sure to leave these instructions with the consumer. Note to Consumer – Keep these instructions for future reference. Skill level – Installation of this custom panel kit requires a qualified installer or service technician.
Installation STEP 4 SECURE CUSTOM PANEL TO METAL MOUNTING PANEL STEP 7 REINSTALL ORIGINAL Ŷ Lay the custom panel, appearance side down, on a clean surface. Ŷ Remove all tape and packing material from the metal panel. Ŷ Place the flat side of the metal panel onto the back side of the custom panel, with the mounting flanges facing up. Ŷ Align the lamp hole in the panel with the mounting panel. Ŷ Confirm squareness and correct position of the metal panel to the custom panel.
Installation Instructions BEFORE YOU BEGIN Read these instructions completely and carefully. Ŷ IMPORTANT – Save these instructions for local inspector’s use. Observe all governing codes and ordinances. Ŷ Note to Installer – Be sure to leave these instructions with the Consumer. Ŷ Note to Consumer – Keep these instructions for future reference. PROFESSIONAL STYLE PANEL ACCESSORY KIT ZXD9030P STEP 2 REMOVE ORIGINAL DRAWER FRONT Ŷ Remove the three screws from the bottom of the drawer edge.
Notes 31-10700-6 13
Notes 14 31-10700-6
Notes 31-10700-6 15
NOTE: While performing installations described in this book, safety glasses or goggles should be worn. For Monogram® local service in your area, call 1.800.444.1845. NOTE: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice.