:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions 30″ Chimney Vent Hood For Model: ZV830 01-08 JR GE Monogram at ::rangehoods.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Safety Information READ AND SAVE THESE INSTRUCTIONS BEFORE YOU BEGIN Read these instructions completely and carefully. • IMPORTANT — Save these instructions for local inspector’s use. • IMPORTANT — Observe all governing codes and ordinances. • Note to Installer — Be sure to leave these instructions with the Consumer. • Note to Consumer — Keep these instructions with your Owner’s Manual for future reference.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Design Information CONTENTS Design Information Product Dimensions and Clearances ....................................................3 Installation Options ........................................................................................3 Installation Preparation Advance Planning, Ductwork, Framing ................................................4 Power Supply ...................................................
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Preparation ADVANCE PLANNING • Determine the exact location of the vent hood. • Plan the route for venting exhaust to the outdoors. • Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 ft. equivalent length for any duct configurations.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Preparation DUCT FITTINGS This Hood Must Use an 8″ Round Duct. It Can Transition to a 3-1/4″ x 12″ Duct. Use this chart to compute maximum permissible lengths for duct runs to outdoors. Duct Piece Dimensions Round, straight 3-1/4″ x 12″ straight Equivalent Length* 1 ft. (per foot length) Total Quantity Equivalent Used Length 1 ft.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) Tape measure Knife Spirit level Measuring tape Wire cutter/stripper Wire nuts Electric drill with 1/8″ and 3/8″ bits Phillips and flat blade screwdrivers Hammer Pliers Pliers Safety glasses Aluminized duct tape Tape to mount template Gloves to protect against sharp edges Aluminized 120V 60Hz.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Preparation CHECK INSTALLATION HARDWARE Locate the hardware package packed with the hood and check contents.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE DUCTWORK, WIRING LOCATIONS Determine the exact location of the vent hood. • Locate the template packed with the literature. – Measure 36″ from the floor to the top of the cooking surface. Add hood installation height determined on page 7. Mark that location. – Use a level to draw a straight pencil line on the wall.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 2 INSTALL HOOD MOUNTING SCREWS The two upper mounting screws must enter the horizontal support or wall studs. • With the template taped in place, use a punch to mark mounting bracket screw locations. • Drill 1/8″ pilot holes in 2 of the punched locations in the lower bracket. • Remove the template.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 5 CONNECT DUCTWORK • Remove shipping tape from the damper. • Install ductwork, making connections in the direction of airflow as illustrated. • Push duct over the exhaust outlet and damper. • Secure joints in ductwork with sheet metal screws. • Wrap all duct joints and the flange connections with duct tape for an airtight seal.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 6 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—VENTED TO THE OUTSIDE 8 INSTALL FILTERS 9 FINALIZE INSTALLATION IMPORTANT: Check to be sure that the main ON/OFF switch next to the motor is in the ON position. • Check to be sure all tape and packaging materials have been removed. • Refer to the Owner’s Manual for operating instructions.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—RECIRCULATING DUCTWORK, WIRING LOCATIONS • Determine the exact location of the vent hood. • Locate the template packed with the literature. • Measure 36″ from the floor to the top of the cooking surface. Add hood installation height determined on page 7. Mark that location.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—RECIRCULATING 2 INSTALL HOOD MOUNTING SCREWS The mounting screws must enter the horizontal support or wall studs. • With the template taped in place, use a punch to mark mounting bracket screw locations. • Drill 1/8″ pilot holes in 2 of the punched locations in the lower bracket. • Remove the template.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—RECIRCULATING 5 SIZE AND CUT DUCT PIECE • Hold upper air deflector with duct connector against the ceiling. • Measure from the bottom of the air deflector to the top of the hood as shown. Measure length Reduce that dimension by 1″ to facilitate installation. The duct will cover and overlap the deflector and the hood outlets.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—RECIRCULATING 6 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.
:: rangehoods.com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions INSTALLATION—RECIRCULATING 8 INSTALL FILTERS 9 FINALIZE INSTALLATION IMPORTANT: Check to be sure that the main ON/OFF switch next to the motor is in the ON position. • Remove all tape and packing material. • Refer to the Owner’s Manual for operating instructions.