User Manual

active, processor controlled, bi-amped speaker systems
W14As
/
W17As
11
ENGLISH
Control and connection panel
1 IN: balanced input, fitted with a Neutrik
Combo
®
connector which accepts both
3 pin XLR and jack plugs.
2 OUT: balanced output, (in parallel with the
input), using a 3 pin XLR connector.
It allows for easy parallel connection of other
active systems.
Mixer output Input ('IN' socket) of the
speaker system
Output ('OUT' socket) of the speaker
system Input ('IN' socket) of the speaker
system to be connected in parallel.
See 'connectors' and 'parallel connection'
at pages 36 and 37.
3 MASTER LEVEL: master volume control.
Adjusts the input levels of the two built-in
power amplifiers to adapt them to the output
level of the mixer. It also allows to adjust the
speaker volume when this system is used in
parallel with others.
Typical operating setting is at maximum
position.
4 H.F. LEVEL: high frequencies level control.
Note: if you are using a Montarbo mixer
(or any mixer having an output level of 0dB),
for optimum performance it is advisable to
set both the MASTER LEVEL and the H.F.
LEVEL controls fully clockwise (to their
maximum settings).
5 POWER / 0 - I: mains power on/off switch.
6 Mains power cord socket (with built-in
fuse). Use only the factory supplied mains
cable or a suitable cable with a ground
connection and marked with the safety
approvals valid in the country of use.
When installing make sure that it is easy to
get to this connector and to the mains plug.
5
6
34
6
5
21
34
21
Spare fuse
Service fuse
FUSE REPLACEMENT