Instructions / Assembly

8
© 2013 Monte Carlo Fan Company
11/20/2013
The receiver provides the following protective functions
Lock protection- The DC motor has a build-in safety feature
against blade obstruction during operation. If something
obstructs the fan blades the motor will stop operation after
30 seconds of interruption. Please remove obstacles and
reset.
Over 80W protection- When the receiver detects motor
power consumption which is greater than 80W, the receiver
power will shut down and fan operation will cease.
Disconnect the power supply and return power on to the fan
after 5 seconds.
Tips for end users
1. If your fan is operated automatically after installation and power on, it is because your fan is still memorize the previous
setting at factory. Make Remote control setting (learn function) and your fan will be ready for use.
2. If fan or light isn’t working, reset power (turn the power off for at least 5 seconds and then turn the power back) and redo the
remote setting.
3. It is not available to separately operate the remote setting for more than one fan in the same room (in the area where remote
signal can reach to) if they share the same power supply. Separate power supplies (like as using individual wall switches for each
fan) is required if you want to separately control more than one fan in same room.
Install Transmitter wall mount cradle with 2 screws provided.
Move the trim plate out from wall mount cradle and install
the wall mount cradle with 2 screws provided. Replace the
trim plate.
Trim plate
Wall mount cradle