Use and Care Manual

Framing Endwalls
Endwall studs will be pre-cut. Door headers, Door studs and
horizontal purlin will have to be field cut.
Refer to the page(s) labeled Endwall Layouts for proper placement
and measurements of your purlin & door studs.
Illustrations below show connection details for attaching endwall studs
to the groundrail and the rafter, proper placement of the "L" brackets
when framing an opening for a door or fan.
1.
3.
2.
sidewall
height
Width
FRONT ENDWALL
REAR ENDWALL
outside
greenhouse
inside
greenhouse
2'' x 2''
endwall stud
welded
stanchion
groundraill
tek screw
thru stud &
stanchion
rafter
endwall stud
horizontal purlin
2''x6'' flat
bracket
1.install front/rear endwall studs
over the welded stanchions and
secure using #14 tek screws
2. view from inside and at the
end rafter. Connect the endwall
studs to the rafters using 2x6
flat bracket and #14 tek screws
3. when framing a door or fan
opening, install "L" brackets on
the outside of the of the
frame-out.
1.
2.
3.
Door
Opening
"L" bracket on outside of
door studs
groundrail
door stud
endwall horizontal
purlin
door
header
door stud
L bracket
Page 10