Owner`s manual
Page 13
B-Series DV-2 Gas Fireplace
Part No. XG0160 - 080410
Installation
Wiring
Gas Control and Pilot Wiring
B-Series DV-2-I
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Cont rol
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 25. Wiring for the B-Series DV-2-I with Honeywell gas control and pilot.
Wiring for the optional Fan Kit
All B-Series DV-2 î‚¿replaces may be equipped with optional fan kits for
circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included with
the fan kit.
NOTE: If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 27b. Wiring schematic for optional fans.
Figure 27a. Wiring for optional fans.
115/1/60 Supply
G L1 L2
G
L2-WH
L1-BLK
Quick Connect
plug to motor