Owner`s manual
Page 4
B-Series DV-2 Gas Fireplace
Part No. XG0160 - 080410
Installation
Installing and Framing the Fireplace
The B-Series-DV-2 replaces may be installed in any location that main-
tains proper clearances to air conditioning ducts, electrical wiring and
plumbing. Safety, as well as efciency of operation, must be considered
when selecting the replace location. Try to select a location that does
not interfere with room trafc, has adequate ventilation, and offers an
accessible pathway for Direct Vent installation. Refer to page 4 - Vent
Installation for more information.
The replace dimensions are shown below:
Figure 3. Minimum Corner framing dimensions, using a 45° elbow.
Figure 2. Framing dimensions.
* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"
Framing
Top View
Front View Side View
Clearances
These clearances apply to all dimensions except the framed opening,
where the clearance to combustibles is 0". The B-Series DV-2 clearances
to combustible materials are:
B34-DV-2 B38-DV-2
Top - Rear Vent * 7 1/2" 7 1/2"
Top - Top Vent 17 1/2" 17 1/2"
Back 1" 1"
Sides 1" 0"
Floor 0" 0"
Mantle** 8" 6"
* Clearance from the top of the replace to a combustible ceiling
within the replace enclosure.
** Refer to page 12, (Mantels and Surrounds).
Unprotected combustible walls which are perpendicular to the replace
opening, must not project beyond the shaded area shown in Figure 25.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapor barrier. This will reduce
the possibility of a cold-air convection current on the replace.
Figure 1. Fireplace dimensions.
M
N
O
N
P
Q
2" clearance
to corners only
M
N
O
N
P
Q
2" clearance
to corners only
M
N
O
N
P
Q
2" clearance
to corners only
A B C D E F G H I J K L
B34-DV-2 33
3
/
4 31
1
/
2 31
1
/
4 1
1
/
4 18 1 13
3
/
4 21
3
/
4 8 4 7 25
1
/
4
B38-DV-2 37
3
/
4 34
1
/
2 34
3
/
4 1
1
/
4 21 1 15
7
/
8 24
1
/
8 9 4 7 28
3
/
8
M
N
O
N
P
Q
2" clearance
to corners only
M
N
O
N
P
Q
2" clearance
to corners only
M N O P Q S T
B34-DV-2 36
3
/
4 33 15
1
/
2 50 35
3
/
8 30
3
/
8 39
7
/
8
B38-DV-2 39
3
/
4 37 17
5
/
8 56 39
5
/
8 33
3
/
8 42
7
/
8
When installing a shelf over the top of the replace, the following
guidelines must be adhered to: For Rear Vent applications the
minimum clearance from the top of the replace to a shelf is 7 1/2". For
Top Vent applications, the minimum clearance is 17 1/2". (Minimum
2" clearance must still be maintained around the vent pipes.)
Figure 1a. Framing for shelves over the fireplace.
(Dimension "L" refer Figure 1 Fireplace Dimensions.)
Top Vent
Rear Vent
(On Applicable Models)
M
7 1/2
S
Header
Shelf
L
T
17 1/2
Header
MEL Short
Shelf
M
2” Min
WARNING!
When this appliance is installed directly on any combustible mate-
rial other than wood ooring, it must be installed on a metal or
wood panel extending the full width and depth of the appliance.