C38-DV Gas Fireplace
Part No. XG0118B
Removing and Installing
 the Door
Removing the Door:
Remove the trim (as described on the next page) to access the door
latches. Open the latches by pulling Part A upwards and towards you
to disengage Part B from the door. Lift Part B clear of the door.
Repeat for all three latches. Be sure to hold the door carefully so it
does not fall. (See figure 23a.)
Installation
Once the three latches are unhinged, tilt the top of the door forward
and lift it out of the slots. See figures 23b and 23c.
Figure 23a.    Operating  the  door  latches.
Figure 22a.  Wiring for optional air circulating fan kit.
G
L1-WH
L2-BLK
Quick Connect
plug to motor
Wiring for the optional Fan Kit
All C38-DV fireplaces may be equipped with optional fan kits (Part
no.  RFK1001,  RFK1003,  RFK1006  or  RFK1007)for  circulating  heat
into the living space.
Installations in  Canada  which  employ  the  fans  must  be electri-
cally grounded in accordance with CSA C22.1 Canadian Electrical
Code Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be
grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70-
1987.
For  more  information see  the  Fan  Kit  Installation  Guide  included
with the fan kit.
NOTE: If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 22b. Wiring  schematic  for  optional  fan kit.
115/1/60 Supply
G L1 L2
Figure 23b.    Removing  the  door.