Installation guide

Page 12
Part No. XG0509
DFSP Rio Pedestal Stove
Quality Gas Products by Montigo
Installation
Wiring for the optional Blower Kit
The Rio Steel Stove may be equipped with an optional variable speed
blower kit (Part #RFK1080) for circulating additional heat into the
living space.
Installations in Canada which employ the blower kit must be electri-
cally grounded in accordance with CSA C22.1 Canadian Electrical
Code Part 1 and/or Local Codes.
Installations in the USA which employ the blower kit must be
grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70-1987.
For more information see the
Installation Guide included with the
blower kit.
Figure 30a. Wiring for optional air circulating blower kit.
NOTE: If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 30b. Wiring schematic for optional blower kit.
1
Optional Fan Switch
Motor
Speed Control
15/1/60 Supply
G L1 L2
Back log
Left log
Right log
Front log
Center logs
Figure 28. Log placement as seen from the front of the stove.
NOTES:
If the logs are not placed properly, excessive sooting will result.
The surface of the logs will crack due to the heat from the
flames. This is a normal occurance.
Gas Control and Pilot Wiring for optional Intermittent
Pilot (-I models) Ignition
Figure 29. Wiring for the Rio Stove with Honeywell gas control and
pilot.
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junct
ion Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grn
d Screw
Wiring