Installation Operation & Maintenance Installation and service must be performed by a qualified installer, service agency, or the gas supplier. H-Series DF Outdoor Gas Fireplace H42DF-O Safety Notice: Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
Warning: Read this manual before installing, operating or troubleshooting this appliance. Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a Montigo gas fireplace, an elagent and well designed gas fireplace built to your specifications. The Montigo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and engineering standards.
H42DF-O Outdoor Gas Fireplace Introduction Thank You for choosing a Montigo Gas Fireplace. About this Fireplace: The H42DF-O is an outdoor fireplace' with a linear-style burner. This fireplace can be converted to both a Top Vent or Rear Vent application, and are only available in a H42DF-O model. The H42DF-O is rated for Natural Gas at 34,000 Max. BTU/H (9.96) Kilowatts Input and 28,000 Min. BTU/H (7.33) Kilowatts. ► H42DF-O; Top or Rear Vent convertible, Millivolt Pilot (LP Models Top Vent ONLY).
H42DF-O Outdoor Gas Fireplace Installation Installing The Fireplace Shell Framing The fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for Direct Vent installation.
H42DF-O Outdoor Gas Fireplace Installation Installing The Gas Line Vent Installation The gas line must be installed before finishing the H42DF-O Fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T.
H42DF-O Outdoor Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations 11 MTO-3F (4"/7") PTO-3F (5"/8") 11 MTKOG (4"/7") PTKOG (5"/8") 1. Frame the termination opening to 11" x 11". 2. Fasten the termination to the studs using a minimum of 4 screws. Installing Terminations with MSR Frames 12 1. Ensure that the two long mounting brackets are facing the bottom of the termination. (See inset).
H42DF-O Outdoor Gas Fireplace Installation Converting to Top Vent/ Rear Vent H-Series DF Top Vent Use the following instructions to convert an H42DF-O for Top Vent use: 1. Install the 4" or 5" inner flue cap on the rear flue outlet and secure the cap in place with five screws, as shown in figure 7a. 2. Install the 7" or 8" outer flue cap on the rear flue outlet, and secure it with five screws, as shown in figure 7a.
H42DF-O Outdoor Gas Fireplace Installation Top Vent Venting Runs For the H42DF-O Top Vent, there are two types of installations: A) Through-The-Wall Installations and B) Vertical (Through-The-Roof) Installations. A) Through-The-Wall Installations Before you install any venting, you must determine whether the venting run will be acceptable. Unacceptable venting can affect the fireplace's combustion.
H42DF-O Outdoor Gas Fireplace Installation Horizontal Venting RHS8 Heat Shield 90° Elbow Termination MEXT Section PEXT Section RHS8 Heat Sheild Figure 13. RetractedInstallationusingacombinationofsolidandflex venting.Usetheventgraphtodetermineyourallowable run, then select appropriate components. Figure11.TypicalTopVentinstallation.Thesolidsectionscanbeusedin variouscombinationstoobtainthedesiredventrun.Thevent run must fall within the limits set by the venting graph.
H42DF-O Outdoor Gas Fireplace Installation Example: Typical vent installation. 20' vertical vent 2 - 2' offsets required 25% of 20' = 5' max. offset allowed This venting configuration meets requirements.
H42DF-O Outdoor Gas Fireplace Installation Reduced Vertical Installation Rear Vent Venting Runs It is possible to reduce vertical vent runs from 5"/8" venting to 4"/7" venting. Reduced vertical venting may only be used when the installation exceeds 12 feet and terminates through the roof, and if the vertical vent reducer is used with the following venting configuration.
H42DF-O Outdoor Gas Fireplace Installation B. Multi-Elbow Installations 2. 45° Corner Installation. Attach an EEL-45/PEL-45 (45° elbow) directly onto the flue collar. Cut the EXT-18/PXT-20 to suit, and attach it to the EEL-45/PEL-45. Slide the fireplace into position and attach to the termination. For more difficult installation situations, the H42DF-O Rear Vent may be installed with two - 90° elbows and up to 15' of horizontal run.
H42DF-O Outdoor Gas Fireplace Installation Installation Of Rear Vent DV Finishing Around the Fireplace The following venting components are available for an H42DF-O in a Rear Vent installation: Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 24. Side wall clearances are 3".
H42DF-O Outdoor Gas Fireplace Installation Removing and Installing the Door Drywall/ Sheetrock Header Non-Combustible Facing Material Removing the door: 6” The doors are removed in a few simple steps. Follow these Steps below to remove the Horizontal access panel, unlatch the door buckles and, remove the door. Replace in reverse order. Step 1: Remove the Horizontal Access Panel: Remove the Horizontal cover by placing fingers in both finger holes, then pushng away from you and lifting out.
H42DF-O Outdoor Gas Fireplace Installation WARNING! Step 5: Do not attempt to clean glass when hot. Ensure the tool is firmly in the lower end of the slot, (as shown), Then pull toward you (Caution: hold the tool securely). L42DF-ST Do not clean glass with abrasive materials as any glass etching may cause premature glass failure. 2 Figure 28d. Do not operate this fireplace without the glass door, or with a broken glass door.
H42DF-O Outdoor Gas Fireplace Installation H42DF-O the underside of the logs, as shown above, figure 30c insets. Installing the Log Set Installing the Logs: The H42DF-O is supplied with a seven ceramic fibre log logset. Unpack the logs and handle them very carefully. Step 5. Place the Centre Front log , Figure 30d below, as shown using the notch cast in the Bottom Rear log as shown in figure 30c above. Step 1. Remove the glass door as described on Page 15.
H42DF-O Outdoor Gas Fireplace Installation H42DF-O Installing the Alternate Log Set Installing the Logs: The H42DF-O is supplied with a seven ceramic fibre log logset. Unpack the logs and handle them very carefully. Step 1. Remove the glass door as described on Page 15. Air Inlets Rear / Bottom Log Fireplace Base Log A Pilot Assembly Log E Figure 30e. Top Right Log, (Log E).. Air Inlets Step 6. Place Front Right log (Log E) as shown in figure 30e. Notch in Log Fireplace Base Figure 30a.
H42DF-O Outdoor Gas Fireplace H42DF-O Operation - Model H42DF-O with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
H42DF-O Outdoor Gas Fireplace Operation - Model H42DF-O-I H42DF-O-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas.
H42DF-O Outdoor Gas Fireplace Operation Maintenance Lighting Instructions General ■ Have the fireplace and installation inspected yearly. The inspection must include, but is not limited to, the following: See pages 19 and 20. Burner Adjustment The H42DF-O is equipped with an adjustable burner, allowing you to raise or lower the flames. To adjust the flames, locate the black knob marked 'Hi-Lo', in the centre of the gas control valve (See Figure 32). The front burners are not adjustable.
H42DF-O Outdoor Gas Fireplace Maintenance Gas Control Valve Troubleshooting Power Generator HONEYWELL SV9500 /9600 Troublshooting Sequence Pilot Adjustment Screw Wall Switch NOTE: Before Troubleshooting, Familiarize Yourself With START The Startup And Checkout Procedure. Manifold Pressure Test Connection Spill Switch SV9500 / SV9600 is powered (24VAC nominal) NO Figure 33. Sit Nova 820 gas valve. Pilot Burner Adjustment YES 1. Locate Pilot Adjustment Screw. (See figure 34.) 2.
H42DF-O Outdoor Gas Fireplace Maintenance Spare Parts - H42DF-O H42DF-O H42DF-O-I NG Gas Valve RGC1006 RGC1004 LP Gas Valve RGC1005 RGC1003 NG Pilot RPA020 RPA003 LP Pilot RPA021 RPA004 Burner NG RBH4201SS RBH4201SS Burner LPG RBH4202SS RBH4202SS ROR1124 ROR1124 ROR1125 ROR1125 RDTH42SS RDTH42SS RLGSH42 RLGSH42 RLGSH42B RLGSH42B Door Log Set Log Base Page 22 Part No.
H42DF-O Outdoor Gas Fireplace Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
H42DF-O Outdoor Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [16 inches (41 cm) minimum] N= B = clearance to door, or sides and top of window, that may be opened [16 inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)] P = clearance under veranda, porch, deck, or balcony [16 inches (41 cm) minimum‡ to non-combustibles] [22 inches (56 cm) minimum‡ to combustibles] clearance above paved sidewalk or a paved d
H42DF-O Outdoor Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.
XG0149 - 010909 Canadian Heating Products Inc. Montigo Del Ray Corp.