Converting to Top Vent/ Rear Vent
H-Series DF Top Vent
Use the following instructions to convert an H42DF-O for Top Vent
use:
Install the 4" or 5" inner ue cap on the rear ue outlet and secure 1.
the cap in place with ve screws, as shown in gure 7a.
Install the 7" or 8" outer ue cap on the rear ue outlet, and secure 2.
it with ve screws, as shown in gure 7a.
Install the ue gasket material and ue cover plate on the rear vent 3.
outlet . Fasten the plate with four screws, as illustrated below.
Install the 4" or 5" inner ue collar and the 7" or 8" outer ue 4.
collar in place on the top vent outlet using 5 screws, as illustrated
below.
Figure 7a. Flue cap installation for Top Vented replace.
Figure 7b. Flue collar installation for Top Vented replace.
Figure 8a. Flue cap installation for Rear Vented replace.
Figure 8b. Flue collar installation for Rear Vented replace.
H-Series DF Rear Vent
Use the following instructions to convert an H42DF-O for Top Vent
use:
Install the 4" or 5" inner ue cap on the top ue outlet and secure 1.
the cap in place with ve screws, as shown in gure 8a.
Install the 7" or 8" outer ue cap on the top ue outlet, and secure 2.
it with ve screws, as shown in gure 8a.
Install the ue gasket material and ue cover plate on the top 3.
vent outlet. Fasten the plate with four screws, as illustrated in
gure 8b.
Install the 4" or 5" inner ue collar and the 7" or 8" outer ue 4.
collar in place on the rear vent outlet using 5 screws, as illustrated
below.
Important: Natural Gas and Propane equipped models
may be installed using Top or Rear Vent applications.
However, the Propane equipped H42DF-O models must
be installed in a top vent application only.
5” Inner Flue Cap
8” Outer Flue Cap
5” Inner Flue Cap
8” Outer Flue Cap
5” Inner Flue Collar
8” Outer Flue Collar