Converting to Top Vent/ Rear Vent
H-Series DF Top Vent
Use the following instructions to convert an H42DF-O for Top Vent
use:
Install the 4" or 5" inner ue cap on the rear ue outlet and secure 1.
the cap in place with ve screws, as shown in gure 7a.
Install the 7" or 8" outer ue cap on the rear ue outlet, and secure 2.
it with ve screws, as shown in gure 7a.
Install the ue gasket material and ue cover plate on the rear vent 3.
outlet . Fasten the plate with four screws, as illustrated below.
Install the 4" or 5" inner ue collar and the 7" or 8" outer ue 4.
collar in place on the top vent outlet using 5 screws, as illustrated
below.
Figure 7a. Flue cap installation for Top Vented replace.
Figure 7b. Flue collar installation for Top Vented replace.
Figure 8a. Flue cap installation for Rear Vented replace.
Figure 8b. Flue collar installation for Rear Vented replace.
H-Series DF Rear Vent
Use the following instructions to convert an H42DF-O for Top Vent
use:
Install the 4" or 5" inner ue cap on the top ue outlet and secure 1.
the cap in place with ve screws, as shown in gure 8a.
Install the 7" or 8" outer ue cap on the top ue outlet, and secure 2.
it with ve screws, as shown in gure 8a.
Install the ue gasket material and ue cover plate on the top 3.
vent outlet. Fasten the plate with four screws, as illustrated in
gure 8b.
Install the 4" or 5" inner ue collar and the 7" or 8" outer ue 4.
collar in place on the rear vent outlet using 5 screws, as illustrated
below.
Important: Natural Gas and Propane equipped models
may be installed using Top or Rear Vent applications.
However, the Propane equipped H42DF-O models must
be installed in a top vent application only.
5” Inner Flue Cap
8” Outer Flue Cap
5” Inner Flue Cap
8” Outer Flue Cap
5” Inner Flue Collar
8” Outer Flue Collar
5” Inner Flue Collar
8” Outer Flue Collar